1)  autocollimator
自准直光管
1.
A series of coordinate systems is set up on a perpendicular axis,and by the attitude relations among coordinate systems,the equations of readouts of the level instrument and the autocollimator are deduced when they areused to measure the wobble error of the axis system.
在某回转轴系上建立了一系列坐标系 ,通过坐标系之间的姿态关系分别推导了用水平仪测试法和自准直光管测试法测试主轴轴系倾角回转误差时水平仪和光管的读数表达式。
2)  Auto-collimation method
自准直法
1.
Measurement of refractive indices of ZF5 glass by auto-collimation method;
用自准直法测量ZF5玻璃的折射率
2.
338μm) in the range from 30℃ to 170℃ were measured by auto-collimation method.
根据Er:Sr3Gd(BO3)3(Er:SGB)的透过率曲线粗略估计了该晶体的折射率,再利用自准直法,精确测量了30~170℃范围内,0。
3)  auto-collimating
自准直
1.
In the system, both auto-collimating beam and position sensitive detector are introduced to detect tiny angle of electrical vibration table.
该系统采用自准直光路原理,利用位置敏感传感器对电振动台微小角度进行精密检测。
2.
In the system,both auto-collimating beam and PSD which has high resolution of displacement are introduced to detect tiny angle of electrical vibration table.
该系统采用自准直光路原理,利用PSD对位置的高分辨能力特性,对电振动台微小角扭动进行精密测量。
4)  autocollimator
自准直仪
1.
Precise center location algorithm for circle target in CCD laser dual axis autocollimator;
激光CCD二维自准直仪中圆目标中心精确定位算法
2.
Development and applications of the OEA 1 TV autocollimator;
OEA-1电视自准直仪的研制及应用
3.
Research and Design of the Digital Optoelectronic Autocollimator;
数字光电自准直仪的研究与设计
5)  self-collimation
自准直
1.
Analysis of self-collimation and subwavelength imaging in one-dimensional metal-dielectric structure;
一维金属-介质周期结构的自准直特性和亚波长成像
2.
The Research of Two Dimensional Photonic Crystal Devices Based on the Interference of Self-collimation Beams;
基于自准直光束干涉的二维光子晶体器件研究
3.
A flat dispersion relation exists at this frequency, which is suitable for the self-collimation.
利用平面波展开方法计算了波状结构二维光子晶体(2DPC)的等频面,对等频面内矩形轮廓的等频线进行研究,提出了波状结构2DPC的自准直特性,运用时域有限差分(FDTD)方法模拟了波状结构2DPC在不同入射角情况下对所入射高斯光束的自准直作用。
6)  auto collimation
自准直
1.
Focused on the dynamic precision measurement of the optical moving target,a suit of experimental equipment of measuring the dynamic precision of the optical moving target by auto collimation was developed,and the principle and the process of it were proposed in this paper.
针对光学动态靶标动态精度的测量问题,研制了一套自准直法检测光学动态靶标动态精度的实验装置,对实验原理和实验过程进行了阐述,并对该系统进行仿真计算,结果表明该系统精度满足使用要求;介绍了光学动态靶标轴系精度的傅立叶级数展开的分析方法,对光学动态靶标动态精度进行了分析。
参考词条
补充资料:平行光管及自准望远镜
      能提供一无穷远目标或平行光束的光学仪器称为平行光管,它是将一被光源照明的针孔或分划板置于物镜的焦面上而构成。平行光管可作为测试基准,广泛地用于测试工作和对其他仪器的校准工作。从平行光管物镜射出的平行光束,遇到平面反射镜反射后,将循原路返回而被物镜聚焦于针孔上。若无视差,则可凭此判定原光束的平行性。所谓自准望远镜就是无需其他仪器之助能校准光束的平行性的自准平行光管。实际的自准望远镜除将针孔换为分划板外,后面还配上相应的照明机构和观测目镜。自准望远镜是工厂、实验室常用的光学仪器,用来检验角度或角度的变化。例如,上述反射镜若有任何转动,则从视场内光学像位置的变动量便可测出镜子的转动量。一般,自准望远镜测角度的精度在分的量级(格值);若备有测微装置,可测至秒级,甚至十分之几秒级。
  
  自准望远镜有两主要类型:高斯型和阿贝型(图1),高斯型自准望远镜的特点是,分划板中心在光轴上,能严格的自准,视场内瞄准的目标是亮视场上的暗标记(例如十字叉线或标尺),亮度稍低;而阿贝型自准望远镜的特点是,分划板中心不在光轴上,不能严格自准,瞄准的目标是暗视场上的亮标记,亮度较高。两者各有优劣。另外还有双分划板型,兼有上两型的一些优点。通常,在光学车间里使用阿贝型来测量玻璃棱镜的内、外角度;而高斯型则多用到装校车间以检测导轨、平台的平直性及各种部件的准直。例如,利用自准直望远镜来检测沿导轨移动的反射镜的法线方向的变化,可测出导轨的直度等。
  
  图2所示是另一种型式的自准望远镜,它的特点是把分划板刻在充作反射镜的铝层上(要刻透,光从后面照明),既能使分划板中心位在光轴上,又能取亮标记。它综合了高斯型和阿贝型的优点。若在其中加上内对焦机构,便成为目前得到广泛使用的内对焦自准望远镜。
  
  图3所示是当前较为新型的一种干涉自准望远镜,它以科斯特斯(Ksters)双像棱镜为主要部件,结构十分紧凑,可以携带,使用方便,测角精度约有一个量级的提高,达到0.01″。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。