1)  fault resistance
故障过渡电阻
1.
Compensation algorithm of grounding distance protection considering FCL and fault resistance
计及故障限流器和故障过渡电阻的接地距离保护补偿算法
2)  transient fault
过渡故障
3)  fault resistance
过渡电阻
1.
Research on the ability of ultra-high voltage transmission line distance protection standing fault resistance influence;
高压输电线路距离保护克服过渡电阻能力研究
2.
Ground distance relay based on fault resistance calculation;
基于过渡电阻计算的距离保护
3.
The existence of fault resistance may add an additional reactive or capacitive component to the impedance seen by the protection.
正向经过渡电阻故障时,距离保护测量阻抗随着过渡电阻变化的轨迹可以利用故障前保护测量到的电压、电流,经过估算得到。
4)  Transition resistance
过渡电阻
1.
Auto-Measuring system for Track to Earth transition resistance in Subway;
地铁轨地过渡电阻自动测量系统
2.
Analysis and research on the ability of distance protection element standing the influence of transition resistance;
距离保护特性元件躲过渡电阻能力分析与研究
3.
The phase selector has overcome the disadvantage of previous phase selectors influenced by the transition resistance,and the principle of the fault selector is simple.
该选相元件从原理上克服了以往序分量选相方法受过渡电阻影响较大的缺点,原理简单,理论分析和大量的现场数据验证表明能有效可靠地选出故障相别,是高压线路保护实现单相重合闸较为理想的选相元件。
5)  transient resistance
过渡电阻
1.
To improve reaction sensitivity of ground distance relay to high voltage high resistance ground fault, a new type of action criterion of highly adaptive protection boundary for transient resistances is put forward.
为提高接地距离保护对高压电网高阻接地故障反应的灵敏性,提出了一种对过渡电阻Rg具有高度自适应动作边界的新型动作判据。
2.
The method is not influenced by the operating mode of the system and transient resistance.
该方法基本上不受系统运行方式和过渡电阻大小影响。
3.
The ability of zero sequence relay against transient resistance under different running conditions is analyzed in detail.
详尽地分析了零序电抗继电器在各种运行方式下的抗过渡电阻能力 ,零序电抗继电器在理论上具有非常强的抗过渡电阻的能力。
6)  transition resistor
过渡电阻
1.
Analysis of neutral grounded via a transition resistor;
小电流接地系统经过渡电阻接地的分析
2.
A novel arcless on-load tap-changing model is proposed,which adopts inverse parallel high-power thyristor as a control switch and regulates the output voltage by switching corresponding tap-changing windings,and uses thyristor s null-current cut-off characteristic to cancel transition resistor input process to simplify the regulation process and accelerate the regulation speed effectively.
采用反并联大功率高耐压晶闸管作为调节控制开关,利用晶闸管开关在电流过零点自然关断的特点,提出了一种不需过渡电阻的新型电力电子无弧有载调压模型,有效简化了调压步骤,加快了调压速度。
3.
It is found out that the two algorithms can both eliminate the influence of transition resistor on the accuracy of fault location,and both have advantages and disadvantages.
结论表明,此两种算法均可有效消除过渡电阻对测距精度的影响,且各有优缺点,可视具体情况选择其中一种。