1)  overhead line
架空线
1.
Mechanical computation for overhead lines by programming in Visual Basic;
用VB语言编程实现架空线的力学计算
2.
The automatism account and prediction analysis on the regulation of overhead line s relaxation degree by the Excel;
运用Excel实现架空线弛度调整的自动计算和预测分析
3.
Numerical simulations for formation mechanism of mixed-phase ice on overhead lines;
架空线混合凇形成机理的数值解析
2)  overhead transmission line
架空线
1.
The field intensity under overhead transmission lines is analyzed using equivalent charge method.
采用等效电荷法对架空线下的场强进行分析。
3)  overhead lines
架空线
1.
Modal-domain modelling of frequency-dependent overhead lines based on recursion algorithm;
基于递归算法的含频变参数架空线的模量计算模型
4)  aerial conductor
架空线
1.
It descibes methods about choosing the model of dampers,making certain the number of the damper and fixing seats of dampers on aerial conductors.
防振锤被广泛运用于架空线以消耗微风振动的强度,保护架空线免受疲劳损害。
2.
Dampers are widely used on aerial conductor to reduce the seventy of aeolian vibration and the accompanying rate of fatigue damage to conductor strands and fittings.
防报器被广泛用于架空线以减少微风振动的强度和相应导线的疲劳损害,本文通过计算振幅比,提出一种确定架空线防振器安装位置的新方法,供防报设计和施工安装时参考。
5)  overhead line
架空线路
1.
Strategy-making method of overhead line control and undergroundcable retrofitting based on clustering algorithm;
基于聚类算法的架空线路入地改造控制决策方法
2.
Utilizing computer to protract installation curve of overhead line;
利用微机绘制架空线路安装曲线
3.
With consideration of the shortage that the tradition discriminant method of overhead lines of rural power grid is complex and hard to programme, a discriminant algorithm of control climate condition of rural power grid based on iterative technology is introduced.
针对农村电网架空线路控制气象条件的传统判断算法繁琐,不适合计算机处理的问题,提出了基于迭代技术的农村电网架空线路控制气象条件的判定算法。
6)  overhead transmission line
架空线路
1.
Calculation of lightning withstand level for energy-user overhead transmission line and improving measures;
用户架空线路耐雷水平的计算与改善措施
2.
The formation and classification of lightening overrating voltage and the ways for regular and irregular lightening-proof of the overhead transmission line are introduced.
结合本单位农村电网送配电架空线路防雷措施设置现状,对加强农网输配电架空线路防雷措施进行探讨,并提出了相应的措施。
参考词条
补充资料:架空线微风振动


架空线微风振动
aeolian vibration of overhead line

之不能出现卡门气流旋涡。风速上限值随导线悬挂点离地面高度的增加而提高,通常达到8~10m/s。风向是振动持续稳定的必摇条件,当风向与导线轴线之间的夹角在450以上时.导线振动是稳定的,当此夹角在300~45’时,振动的稳定性很小,而当此夹角小于200时,一般不会发生振动. (3)档距长度。徽风振动以一个档距为独立的振动单元.档距愈大,由于档距长度等于半波长的整数倍的振动绷率值愈密集,故建立稚定振动的机率愈大,即振动持续时间增加。另一方面,风传输给导线的振动能t与档距长度成正比,这给大档距的防振设计带来很大困难。对于档距长度为10Om以下的小档距,不仅出现振动的机率很小,同时档距端部的阻尼作用对振动有很大的影响,故小档距一般不藉装设消振装盆. (4)导线张力.为了说明导线张力对振动的影响,引入了导线平均运行应力(通常用EDS表示)的概念,它是指年平均气沮及无外荷载条件下的导线水平应力,习惯上将此时导线张力值用导线极限强度(通常用UTS表示)的百分数来表示。提高导线张力会使导线本身的阻尼作用减小,并且导线的允许疲劳强度也随张力的提高而降低。因而提高导线张力增加了振动的危险性.国际大电网会议(CIGRE)根据各国提供的线路运行经脸进行总结,规定了一般情况下导线张力的上限值为25%UTS,这与中国根据线路的运行经验褥到的结论相同.另一方面,限制提高导线的张力必然会增加线路的建设投资。若将规定的EDS上限值作为一个绝对标准,而不考虑导线构造设计的差别,也会导致严重的振动后果,是不经济的。因此,正确地估价导线张力的影响,应从导线的阻尼作用来分析,例如结构设计相同而采用高强度材料制造的导线,应取用较低的EDS值,如果改变导线的结构设计而提高了阻尼作用,则可能取用较高的EDS值。自阻尼导线就是一种特殊结构设计的导线,其EDs值可提高到35%UTs左右,从而明显地降低了线路的造价,并解决了大跨越线档严重的徽风振动问题。 (5)惫垂线夹。虽然悬垂线夹对振动强度并无影响,但振动现象却是通过悬垂线夹转变为动态应力作用于导线的。实际运行经验说明,由于悬垂线夹的型式、性能及质t等方面的差异,或者由于安装使用不当,都会造成疲劳断股情况的极大差别。20世纪50年代曾一度认为悬垂线夹是防止导线疲劳断股的关键,企图设计一种“防振线夹”。基于这种观点研制成功了预纹丝型悬垂线夹,可以达到比较满愈的运行效果。现在对惫垂线夹的设计原则已充分考虑了徽风振动的特点,使各种常规的悬垂线夹已具有满意的防振性能。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。