您的位置:首页 -> 词典 -> 封闭母线
1)  enclosed bus
封闭母线
1.
This paper introduces the fault course that the stator ground protection alarming and tripping caused by generator enclosed bus wetting of units 3 & 4 in Zhangjiakou Power Plant,analyzed the cause of null sequence voltage alarming of unit 3 and the handling measures.
简单介绍了大唐国际张家口发电厂3、4号机组由于发电机封闭母线受潮导致定子接地保护报警、动作跳闸的事故经过,分析了3号机组零序电压报警的原因及处理措施。
2.
Along with the universal application of large generator, the enclosed bus with big current for generator outgoing line is adopted extensively.
随着大容量发电机的普遍应用,发电机出线的大电流封闭母线也被广泛采用。
3.
The selection and determination of isolation level of isolated-phase enclosed bus and cooling mode are introduced.
重点介绍了公伯峡水电站离相封闭母线绝缘水平和冷却方式的选择和确定,并对离相封闭母线的几个重点问题如结构特点、接地、与相关设备的连接、短路试验装置的设置等作了简单介绍。
2)  enclosed bus-bar
封闭母线
1.
The enclosed bus-bar is the important equipment in the power transmission.
封闭母线是进行电力传输的重要载体,封闭母线的发热损耗一直是困扰着电能运输及有效利用的重要问题。
2.
The rated current of enclosed bus-bar main circuit is 36 000 A for 1 250 MW units in Shandong Haiyang and Zhejang Sanmen Nuclear Power Stations.
山东海阳及浙江三门核电1 250 MW机组离相封闭母线主回路的额定电流为36 kA。
3.
The forced air-cooling enclosed bus-bar is the development trend of the enclosed bus-bar.
强迫风冷封闭母线封闭母线发展的趋势。
3)  enclosed busbar
封闭母线
1.
Technical analysis on the high vertical heavy-current enclosed busbar of Shuibuya Hydropower Station;
水布垭水电站高垂直大电流封闭母线技术分析
2.
With help of ANSYS software, the short circuit electromagnetic force is calculated and analyzed for an enclosed busbar.
借助ANSYS软件对封闭母线进行短路电动力计算和分析,并与理论计算值进行比较。
4)  closed bus
封闭母线
1.
Based on the configuration features of closed bus,the causes of closed bus gas leakage are analyzed,so as to constitute an improved project,then the implementary results of improved project are further introduced.
在介绍封闭母线结构特点的基础上,分析了导致封闭母线气体泄漏的原因,由此制定了有针对性的改进方案,并进一步介绍了改进方案实施的结果。
2.
The closed bus is a section of special lead that connects the generator and transformer.
封闭母线是连接发电机与变压器的一段特殊导线,其工作特点是低电压,高电流,电流可达数万安培,电压值为38V。
5)  whole-cast closed bus
全浇注封闭母线
1.
The HV whole-cast closed bus adopts anticorrosive inorganic mineral material as insulation material,has no protective shell.
中压全浇注封闭母线采用完全防腐蚀的无机矿物质材料作为绝缘材料,不需要任何外壳保护,可承受较大的冲击力,因其绝缘性能优良,母线体积相对较小。
6)  enclosed bus duct
封闭式母线槽
补充资料:均衡母线接线


均衡母线接线
balance-bus scheme

均衡母线接线个发电机一变压器-。黑蓄竺亡尝、整eme,每-,一“~华/‘侧p理迈另一合断改段位到一组公共均衡母线的主接线方式.这种接线是由变压器一线路组接线演变而成,增设了均衡母线,可使各回路间电能均衡分配。也可认为是一个半断路器接线去掉一组母线和一台断路器的简化接线方式。按均衡母线断路器位置,可分为外均衡母线接线(均衡母线断路器接在线路侧)和内均衡母线接线(均衡母线断路器接在变压器侧),分别见图(a)、(b)。┌───┬─────┬────┐ ├挚¨┐│ 1 │.、 │ │ 、│├蛰-%┐ │ │ │ ││ 、│ ├───┬┼─┐├──┴┼──┘ │.臼.- ││ ││} │ │ 班 ││ ││ │ ├───┘└─┘└───┴─────┘ 均衡母线接线 (a)外均衡母线接线,(b)内均衡母线接线 这两种接线方式的共同优点是:①接线清晰.②布置简单。③运行方便,故障影响范围小,运行可靠性较高,尤其对线路物送功率和发电机容量相当,或者输电线路基本送往同一方向或同一变电所时最为适用。共同缺点是:①灵活性差,均衡母线检修,全部解列成各自单独的发电机一变压器一线路组单元运行.②均衡母线上的断路器故障,除影响本回路变压器一线路组单元停电外,其他单元也将解列运行。 外均衡母线接线的优点是:①主变压器的投人或切除比较方便。②一台主变压器故障只开断一台断路器,不影响线路的运行。缺点是:①出线断路器检修将影响发电机变压器组送电。②线路故障需同时开断两台断路器,并需满足并联开断的要求。 内均衡母线接线的优点是:①线路的投人或切除比较方便。②一回线路发生故障时,仅故障线路的断路器断开,不影响其他回路的运行.缺点是:①一台主变压器故障,同时开断两台断路器,并切除一回线路。②主变压器的投入或切除需同时开断两台断路器,并影响线路的运行。 均衡母线接线一般适用于进出线回路数相同,出线负荷较稳定,且负荷基本与发电机容量相一致,并且电力系统允许按发电机一变压器一线路组单元运行的大中型水电站.当电站利用小时数较低,担负调峰任务,主变压器切合频萦时,一般采用外均衡母线接线。