说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 反应调整系数
1)  response modification factor
反应调整系数
1.
In this paper,the response modification factors(RMFs) of reinforced concrete shear walls in different performance levels are first determined according to the difference in seismic capacity of the walls under different performance statuses.
根据不同性能状态下钢筋混凝土剪力墙抗震能力的差别,确定不同性能等级下剪力墙的反应调整系数
2.
The response modification factor is introduced to evaluate the seismic capacities of the reinforced concrete(RC) shear walls of tall buildings,and to quantitatively articulate the seismic fortification measures prescribed by the China codes.
为明确高层钢筋混凝土剪力墙的抗震能力,采用反应调整系数量化现有规范中剪力墙的设计构造措施,推导并计算了独立矩形悬臂剪力墙的超强系数和延性系数,从而确定了各抗震等级剪力墙的反应调整系数,再与设防地震和多遇地震的地震动比值相比较。
2)  adjusting coefficient
调整系数
1.
According to contrast test,analysis on bearing capacity size effect about pier foundation is carried,the result shows the adjustment coefficient appears the series of regular decreasing powers following the rise of pier floor\'s diameter,and get an adjusting coefficient curve about pier floor\'s size effect.
根据对比试验,分析了墩基础的尺寸效应对承载力的影响问题,得出随着墩底直径D值增大,调整系数呈降幂指数规律衰减,并给出了相应的墩底尺寸效应调整系数曲线。
3)  adjustment coefficient
调整系数
1.
Taking the items of"nominal frequency" and"adjustment coefficient" as a specification, this paper provides a practical calculation method for adjusting parameters of power frequency series resonance test equipment, which has been verified both in laboratory and on site.
引入“名义频率”和“调整系数”等参数作为量化依据,提出了一种现场调整工频串联谐振试验装置参数配合的工程计算方法,并已通过了实验室试验及现场参数配合示例的验证。
2.
According to cross wall as the load bearing wall in brick masonry structure and the circumstance of improper foundation width calculated from respective bearing capacity in this paper corresponding width adjustment coefficients are revealed for the buildings with 6-7 stories.
针对横墙承重砖混结构中的纵横墙,按各自所承受的荷载计算出的基础宽度不合理这一现象,就一般的六、七层住宅,给出了相应的纵横墙基础宽度的调整系数,供设计施工人员参考使用。
3.
The paper explains how to use the methed correctly in view of the selection of testing imstrument,the plate steel of sticking management of pile head,the selection of hammar vibrate energy, the structure of piecing hammer,and adjustment coefficient Kv etc.
本文从测试仪器的选用、桩头处理粘贴的钢板、激振能量的选择、穿心锤的构造、调整系数Kv的确定等方面,说明了如何正确使用该法。
4)  regulation coefficient
调整系数
1.
Discusses concrete methods of heat metering and charging, introduces the concept of the heat metering and charging regulation coefficient, describes its calculation and two procedures of regulation.
深入探讨了住宅供暖计量收费的具体方法 ,引入了计量收费调整系数的概念 ,给出了该系数的计算方法及两种调整方法 ,同时给出了根据单位建筑面积供暖收费标准和单位建筑面积热负荷换算热价的方
5)  Coefficient adjustment
系数调整
1.
The algorithm simulated the effect of coefficient adjustment on the classifier result, chose the best direction of the classifier result and designed the optimization mechanism.
算法模拟弱分类器系数增加或减少对分类结果的影响,选择最利于分类的系数调整方向,设计了优化机制。
6)  reaction coefficient
反应系数
1.
Analysis and determination of items amount of reaction coefficient for unsteady heat transfer calculation of wall;
墙体不稳定传热计算中反应系数项数的分析与确定
2.
Two kinds of reaction coefficient of heat transmission & absorption;
建筑外围护结构的两类传热与吸热反应系数
3.
Considering the heat effect of solar radiation and fluctuation of temperature on the outside surface of building envelope,adopting a reaction coefficient method,with the typical-year meteorological date of Tianjin,the unsteady thermal output in successive time of sixteen building mold nets with exterior insulation is calculated by different direction.
考虑太阳辐射和气温波动对围护结构外表面的热作用,利用天津市典型年气象资料,采用反应系数法,对16种外保温建筑模网墙体按朝向分别进行逐时不稳定传热量计算。
补充资料:反应性系数


反应性系数
reactivity control

  fony一ngxlng kongzhl反应性控制(reaetivity control)对反应堆内刹余反应性的控制。其主要任务是采取不同的控制方式,在确保安全的前提下,控制反应堆内的剩余反应性,以满足反应堆长期运行的需要;通过控制毒物适当的空间布t和最佳的提棒程序,使反应堆在整个堆芯寿期内保持较平坦的功率分布,尽可能地减小功率峰因子.在核电厂负荷变化时,能自动调节反应堆内反应性,使之响应负荷的变化;当反应堆出现异常现象或事故时,能迅速安全地停闭反应堆,并保持适当的停堆深度。 凡是能够有效地影响反应堆内反应性的任何装里、机构和过程都可以用作反应性的控制.概括起来有四种反应性控制方法:中子吸收法、改变中子慢化性能法、改变燃料含量法以及中子泄漏法等。 中子吸收法利用在堆芯中添加或移出控制毒物来改变堆内中子吸收。现在大多数杖电厂反应堆上广泛采用的控制毒物有三种:可移动式控制棒、固体可嫩毒物和液体冷却剂中加人可溶性毒物(如翻酸等)。 改变中子慢化性能法多指重水一轻水混合反应堆中,通过调节重水与轻水的比例,来改变反应堆内中子能谱,从而改变反应性的方法。 改变燃料含t法指在用嫩料作控制棒或作控制棒跟随体的情况下,当移动控制棒时,除了改变反应堆内中子吸收之外,还改变反应堆内燃料含量,从而改变反应性。 中子泄漏法利用移动反射层的方法,改变反应堆内中子泄漏量,从而改变反应性. 反应性控制方式的选择与反应堆堆型选择紧密相关。在石墨或重水作慢化剂的反应堆中,由于初始的剩余反应性比较小,控制棒的效率较高,所以多采用棒控制方式。在轻水慢化的反应堆中,初始剩余反应性很大.控制棒的效率又比较低,如果全部采用控制棒来控制,则需要控制棒数目多;又因这类堆芯栅格稠密,设计排列较多控制棒是困难的。此外,为了多安装棒驱动机构装t,在反应堆压力容器上封头就要增多开孔,这将严重地影响其机械强度。所以,当今世界上的压水堆核电厂多采用控制棒和在冷却剂加添适量翻酸两种方式联合控制。这样既减少控制棒的数目,又保证了足够的剩余反应性。但在压水堆核电厂中.为保证反应堆内慢化剂温度系数为负值,冷却剂里翻浓度一般限制在1300Xlo一‘~1400x10一‘以下(见反应性系数),所以在第一次新堆起动前,由于剩余反应性很大,还需要在堆芯里按一定的分布插装固体可嫩毒物棒。沸水堆与压水堆不同,它并不采用在冷却剂中添加翻吸收剂来控制堆内反应性。在小型块中子反应堆中,有的利用移动反射层的办法来改变堆内中子泄泥量以实现对反应性的控制。
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条