说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 故障限流
1)  fault current limiting
故障限流
1.
In this paper, SSMES with fault current limiting function for substation applications is proposed.
文中研究了应用于变电站的具有故障限流功能的SSMES。
2.
A 220 V/25 A/6 kW prototype of superconducting fault current limiting-magnetic energy storage (SFCL-MES) model is designed to test the basic principle of SFCL-MES.
提出了一种用于配电系统的SFCL—MES的系统结构,它由2个串联于变 电站负荷的故障限流端口及1个并联于变电站母线的储能端口组成,既可以限制变电站的短路电 流,又可以提高整个变电站的供电质量。
2)  fault current limiter
故障限流器
1.
Advances of saturated iron core fault current limiters;
磁饱和型故障限流器的研究与发展
2.
Fault Current Limiter with Large Capacity Based on Flux Compensation;
基于磁通补偿的大容量故障限流
3.
Topology and Simulation of a PWM-Controlled Fault Current Limiter;
基于PWM控制技术的故障限流器的拓扑与仿真
3)  FCL
故障限流器
1.
FCL Appliced to Power System;
几种在电力系统中应用的故障限流
2.
The Simulation of Power System Transient Stability Enhanced by FCL;
故障限流器提高电力系统暂态稳定的仿真
3.
A novel solid state Fault Current Limiter (FCL) with bypass reactor for high-voltage electric network is presented.
提出一种适用于高压电网的具有旁路电感的新型固态故障限流器,分析了新型固态故障限流器的工作机理,给出了在各种短路故障情况下的控制策略,并对其进行仿真研究。
4)  fault current limiter
故障电流限流器
1.
In this paper, a fault current limiter with series compensation is proposed.
提出—种新型的具有串联补偿功能的故障电流限流器,它由补偿电容和旁路电感并联后与限流电感串联而成;和旁路电感相串联的可关断晶闸管(GTO)控制正常时的补偿度和故障时的限流程度。
5)  superconducting fault current limiter
超导故障限流器
1.
Design and test of superconducting fault current limiter based on YBa_2Cu_3O_7 thin film;
基于YBa_2Cu_3O_7薄膜的超导故障限流器设计与试验分析
2.
According to the characteristics of superconducting fault current limiters(SFCL),the SFCL can be divided into two types:inductor type and resistor type.
根据超导故障限流器(SFCL)失超后表现出的阻抗特性,可将SFCL分为2类:电感型和电阻型。
3.
Based on the classification of original superconducting fault current limiters, recent progresses of superconducting fault current limiter in power system and international projects are depicted.
着重介绍了电阻型、桥路型、桥路串阻型及全控桥型等几种具有较高应用价值的超导故障限流器的原理及特点,并对限流储能相结合的超导设备原理进行了探讨。
6)  fault current limiter
故障电流限制器
1.
Influence on switching capability of HV circuit breakers by employing rectifier type fault current limiter;
整流式故障电流限制器对高压断路器开合能力的影响
2.
Overseas,some fault current limiters have been put into service.
目前我国某些地区短路电流过高制约着电网发展,故障电流限制器可以快速限制短路电流,保证系统安全稳定运行,是具有发展潜力的限制短路电流技术。
3.
To give an effective solution to fault current suppressing,an series resonant type fault current limiter(FCL) topology based on fast transfer switch is presented,in which a fast transfer switch is used as the short-circuit element for the capacitor.
为限制电力系统短路电流,提出了一种开关作为电容器短路元件的串联谐振型故障电流限制器拓扑。
补充资料:换流站逆变侧交流系统故障


换流站逆变侧交流系统故障
AC system faults on inverter side of converer station

  huanl一uZhonn{b一oneeJ一00!旧xltong guZhong换流站逆变侧交流系统故阵(AC systemfaults on inverter side of eonverter station)直流抽电受端交流系统发生的故障,包括三相短路、两相短路、两相对地短路、单相对地短路以及断线等.在常规的直流物电系统中,逆变器必须在受端交流系统提供的换相电压支持下才能正常工作。交流电网的故障会使逆变站交流母线电压的幅值、相位和波形发生变化,这些变化将可能引起逆变侧控制系统失去同步基准信号、阀触发系统储能不足,或逆变器的换相失败(见换流莽故降).逆变侧交流系统故障对直流系统的形响比整流侧的严重,其形响的程度往往以是否引发逆变器的换相失败或换相失败后是否能自行恢复正常来衡t。 三相对称故瘫,将由于故障地点的远近不同而使换相母线电压的下降程度不同,通常下降至额定电压的70%~60%时,逆变器就可能发生换相失败。由换相电流关系式可推导出三相交流电压下降造成逆变器发生换相失败的极限下降系数,即护万v[eos下。一eos(7。一y。。+600)〕式中。岛为换相电抗;几为直流运行电流,y。为关断角整定值;ym.二为极限关断角;U为故障前交流母线线电压有效值。如果采用低压限流(VDCL)的措施.通常在额定电压的40%时,还可维持直流系统运行。 交流系统不对称故障会使逆变站交流母线各相电压幅值和相位发生不同程度的变化。不对称故障除了降低换相电压外,还引起换相电压过零点的不对称移动,从而又直接影响到换流阀的关断角。通常不对称故障对关断角的影响比对称故障更严重。当逆变侧交流系统发生不对称故障时,逆变器往往会由于关断角变小而发生换相失败。
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条