说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 直流母线负电流
1)  Negative DC current
直流母线负电流
2)  DC-bus current
直流母线电流
3)  DC bus voltage
直流母线电压
1.
To make the servo system have the expected functions,it s especially important for selection of DC bus voltage in servo driver.
在伺服系统中要使系统能够满足所期望的性能,伺服系统驱动器直流母线电压的选择尤为重要。
2.
The direct torque control(DTC) system fed by TSMC was proposed that to control the inverter to implement DTC,and to control the rectifier to correct input power factor,or improve the performance of the DTC system by controlling input current space vector or the scope of DC bus voltage.
根据双空间矢量调制的缺点,提出了逆变环节采用直接转矩控制,整流环节控制输入电流矢量或直流母线电压来实现输入功率因数校正或提高电机系统性能的双级矩阵变换器供电的直接转矩控制系统。
3.
The reason about weakly performance at low speed-lower ratio of voltage signal-to-noise (SNR) was analyzed,and proposed a novel method-adjustable DC bus voltage,to enhance the SNR as well as to improve the low speed performance.
针对永磁同步电动机扩展卡尔曼滤波无传感器控制时低速性能不佳的问题,分析了低速性能不佳的原因——电压信噪比较小,并且提出了提高信噪比的方法——调节逆变器的直流母线电压,来改善系统的低速性能。
4)  DC bus
直流母线
1.
Analysis of a DC bus loss of power and its solutions in the power substation
一起变电站直流母线失电原因分析及解决方案
2.
To ensure the reliability of DC system,the insulation status of DC bus must be entirely monitored online.
为了保障直流系统的安全可靠运行,通常发电厂、变电站使用的直流系统绝缘监测装置是通过检测对称电桥的不平衡程度来反映直流母线的绝缘情况,但当正负母线绝缘均按比例下降时就失效。
3.
However,the use of multi-inverter wiring with a common DC bus, make the power feeding back can be absorbed by other electric motor,and the excess electricity can also be feedback to the power grid through the feedback device,so that power can be fully utilized.
但是采用了多逆变器公用直流母线的接线方式后,电机回馈制动所产生的能量可以被其他电动状态的电机吸收,而且多余的电能还能够通过回馈装置回馈电网,使电能得到充分的利用。
5)  bus current
母线电流
1.
Power supply for high-voltage side lines from medium and high-voltage bus to obtain electric energy was designed,the method to accurately measure bus current by using Rogowski coil given out.
设计了从中高压系统母线获取电能作为高压侧线路供电的电源,给出了利用Rogowski线圈准确测量母线电流的方法。
6)  common DC bus
共直流母线
1.
The common DC bus technology uses the regeneration energy to supply other drives.
共直流母线技术则是使能量通过母线流动供其它传动使用,以达到节能、提高设备运行可靠性、减少设备维护量和设备的占地面积等目的。
2.
This paper introduces the structure and characteristic of common DC bus system.
介绍了共直流母线系统的组成与特点,针对浆纱机多电机变频传动的特点,将共直流母线技术应用到浆纱机中去。
补充资料:换流站直流开关场故障


换流站直流开关场故障
faults in the DC switch yard of converter station

huonlluzhan zh一l一u ko一guonehong guzhong换流站直流开关场故阵(faults in the】X二switeh yard of eonverter station)主要指发生在换流站直流开关场范围内的故库.即从换流器高压端出口至直流线路隔离开关,低压端包括至接地极之间的所有设备或连线的故障。主要包括的设备有平波电扰器、直流滤波器、中性母线、接地极引线、直流断路器和隔离开关,以及直流场内通信滤波装t和直流电流、电压测量装置等。 直流开关场内的高压侧较多发生的是设备支柱绝缘子对地闪络故障,这将引起直流电流瞬时急剧增大,是换流站较严重的故障。当发生故障时,相应的保护动作使直流系统停运。 直流开关场内的低压侧,通常发生的是中性母线或接地极引线对地短路或断线故障。如果发生对地短路故障,直流电流将流过站内接地网,造成站内接地网电位升高,使换流变压器中性接地点流人直流电流,引起直流偏磁增大而产生饱和。如果发生开路故障,则直流电流将中断,并使中性母线设备承受很大的过电压应力。 直流开关场中的设备故障主要指直流滤波器、平波电抗器的故障.直流滤波器可能发生内部短路故障、元部件的过负荷造成元件过热,或者由于支路内电容器元件的损坏数量达到一定程度后而导致电容器组件内的其它电容器元件雪崩式损坏。油浸式平波电抗器故障与变压器故障基本相同。空气绝缘的平波电抗器通常会由于绝缘设计强度或制造工艺问题而引起内部绕组局部发热而损坏。这些故障直接威胁直流系统的设备安全,都将由控制或保护动作而使直流系统停运。直流开关场的开关设备中,比较特殊的是金属回路转换断路器(MRTB)和金属回路转换开关(MRTS)。直流系统在从大地回路运行方式转换为金属回路运行方式时,MRTB需要切断的电流值约达运行直流电流的80%~90%。如果转换不成功,则MRTB必须要经受数百毫秒间隔的拉断电弧的时间,然后才能得到保护发出的重合命令,以避免MRTB的损坏。当系统中发生某些特殊不正常工况时,如大地回路运行而一端接地极损坏或接地极引线断开,同时该端中性母线接地刀闸又闭合时,则可能会有大电流流过站内接地网,造成地网损坏。为避免这种情况的发生,也配备有专门的保护。 对于双极直流输电系统,直流开关场内的大部分故障是由于单极设备的原因引起,只对单极的运行产生影响。但在直流开关场的中性线侧,有一段双极共用的中性母线,发生在该处的对地短路故障或开路故障,将直接影响双极的运行,甚至导致双极停运.直流控制保护系统通常双重化配置,如果双通道的故障切换逻辑失灵,将导致因控制系统全部失去而使直流系统停运。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条