说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 中压电网
1)  medium-voltage power network
中压电网
1.
The harm of single-phase grounding fault current in the medium-voltage power network has been gotten the universal solicitude of people.
中压电网中,单相接地故障电流的危害性受到了人们的普遍关注。
2.
The recent developments of neutral point ground modes of medium-voltage power network and variety of national related standards are presented.
阐述了中压电网中性点接地方式的近况,国家有关标准的变化,企业应从中吸取有益的东西。
2)  MV distribution network
中压配电网
1.
Researches on Tabu search based algorithm for optimization of supply area division in MV distribution network planning;
基于Tabu搜索的中压配电网分区优化算法研究
2.
Combined with the practice and reference to these typical power supply modes, the MV distribution network in area of Beijing Finance Street was retrofitted by Beijing Electric Power Co.
文章介绍了国内外部分大城市中压配电网的典型供电模式,同时对这些典型供电模式进行了优缺点分析。
3.
Derivative connections applied in MV distribution networks are proposed.
衍生出的高负载率的接线模式与配电网自动化配合,具有推迟新建项目的潜在经济效益,优化了整个中压配电网络,并在对比了经济效益的基础上对杭州市规划新建小区提出了应用建议。
3)  MV distribution networks
中压配电网
1.
Research on capacity-load ratio in district MV distribution networks;
地区中压配电网容载比的研究
4)  middle voltage distribution network
中压配电网
1.
Analysis of typical connection modes of urban middle voltage distribution network;
城市中压配电网典型接线方式分析
5)  medium-voltage distribution network
中压配电网
1.
A software system for the quantitative assessment of the reliability of medium-voltage distribution network has been developed on the basis of the reliability theory, graph theory and the object-oriented program technology.
在综合应用配电系统可靠性理论、图论以及面向对象的计算机编程技术基础上,研究开发了一套适用于中压配电网供电可靠性定量分析计算的评估系统软件包。
2.
In order to solve the confliction between the development of 10 kV medium-voltage distribution network and the rapid load increasing in Nanjing district,enhance the network’s power supply ability and adaptability,reduce the power supply cost,it is decided to generalize 20 kV voltage grade based on a technology-economy comparison.
为了解决南京地区10kV中压配电网发展与负荷快速增长的矛盾,提升配电网的供电能力和适应性,降低供电成本,南京中压配电网经技术经济比较后确定由10kV升压至20kV。
3.
A lot of simulations for the 6-35kV medium-voltage distribution network withdifferent neutral grounding techniques have been done by the ATP/EMTP software inthis paper,and the disadvantages of neutral resonance grounded mode and neutralflexible grounded mode have been proposed by in-depth analyses and studies on thesimulation results.
本文对6~35kV的中压配电网中性点接地系统进行了大量ATP/EMTP仿真分析,通过对仿真结果的深入分析与研究,指出了当前的谐振接地方式和灵活接地方式存在的问题。
6)  medium voltage distribution network
中压配电网
1.
For a long time, there have been lots of energy losses in medium voltage distribution networks in China, and it is very difficult to calculate them properly.
长期以来 ,国内中压配电网线损计算困难 ,虽已做过大量研究 ,但仍未完全解决。
2.
According to the requirements,the connections in common use for the medium voltage distribution network are analyzed and compared from the aspects of economy,reliability,flexibility.
针对上述要求,从经济性、可靠性、灵活性等方面对城市中压配电网络的常用接线方式进行了分析比较,并从配电网络接线方式和原理入手,结合实际工作经验,分析配电网接线方式的选择原则,尝试探讨根据不同情况下进行电网接线方式分析和选择的一些措施与建议。
补充资料:冲击波超压与动压

[解释]:  核爆炸产生的高温、高压火球膨胀,在周围介质中形成连续向外传播的压力脉冲(或冲击波),冲击波阵面传播到空间某点时,超过周围环境大器的压力称超压;空气粒子高速随波阵面运动产生的冲击压力称动压。超压和动压都以帕斯卡(Pa)为主单位。超压随时间的变化取决于爆炸威力、距爆点的距离和爆心周围的介质情况。特定地点的峰值超压一般出现在冲击波阵面到达该点的瞬间,超压在该点的持续时间称为正压作用时间。尔后,该点的压力下降到低于周围压力,称为负压,再逐渐回升到周围压力值。对人员的直接冲击伤,超压为20—29千帕可引器轻度伤;29—59千帕可导致中度伤;59—98千帕可造成重度伤;大于98千帕可造成极重度伤。动压为10—20千帕可造成中度伤;20—39千帕可造成重度伤;大于39千帕可造成极重度伤。动压的推动、抛掷和超压的挤压会造成物体变形和毁坏。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。