1)  commutation failure
换流失败
1.
The reason for incorrect action of sudden-change direction protection of 220 kV two sides caused by commutation failure in DC converter station was analyzed.
对因直流换流站换流失败引起220kV线路两侧突变量方向保护不正确动作的原因进行了分析。
2)  commutation
换流
1.
Study on Commutation Technique of Single-phase Matrix Power Converter;
单相矩阵式电力变换器换流技术研究
2.
Improvement of commutation method for directive realizational matrix converter;
直接实现式矩阵变换器换流方法的改进
3)  current commutating
换流
1.
This paper introduces several typical structures of HCB and expatiate on the principle of naturally current commutating and constrainedly current commutating.
介绍了几种混合式断路器的典型结构,阐述了自然换流和强制换流的原理。
2.
The several typical structures of HCB, the principle of naturally current commutating and constrainedly current commutating were presented.
阐述了自然换流和强制换流的原理及IGBT软关断技术。
4)  commutating current
换流
1.
The characteristics of coil damping circuit is studied,the current of damping capacitance and the calculation of resistor power consumption are also proposed by commutating current theory of rectifier.
根据整流桥换流工作原理,研究了绕组阻尼电路的工作特点,给出阻尼电容电流及电阻功耗的计算方法,通过计算分析找出阻尼器件大量损坏的原因;分析了阻尼电容放电电流对晶闸管的危害性;进一步探讨机车操作过电压特点,推荐能兼顾操作过电压、满足阻尼器件和整流装置安全工作的阻尼电路参数。
2.
The interruption and commutating current characteristics are analyzed by ways of combining theory and experiment.
通过理论和实验两方面相结合的方法,分析了断路器系统的开断特性和换流特性。
3.
The operation principle of a direct current circuit breaker, which is used as quench protection in the Tokamak, was introduced, and the law of the commutating current of the circuit breaker was presented with theory and test results in details.
介绍了超导托卡马克装置中失超保护开关———直流快速开关的工作原理,并通过理论和实验分析了其在换流过程中的规律。
5)  transition process
换流过程
1.
This paper mainly introduces the development of power components' transition process,the control technology of inverter power system and the modeling,theoretical analysis and computer aided design of inverter power source.
主要从功率器件换流过程 ,逆变电源系统的控制技术 ,逆变电源的建模、理论分析、计算机辅助分析以及大功率逆变技术应用研究所面临的问题等方面 ,分析和探讨了弧焊逆变技术的现状与发展方向。
6)  converter station
换流站
1.
Noise treatment in Three Gorges-Shanghai ±500kV DC transmission converter stations;
三沪直流工程换流站噪声治理
2.
Research of software architecture of converter station s transformation MIS supporting maintenance decision-making;
支持检修决策的换流站变电MIS软件体系结构探讨
3.
Key factors of site selection for a HVDC converter station;
高压直流换流站的关键建站条件
参考词条
补充资料:电容换相换流器


电容换相换流器
capacitor commutated converters, CCC

d一onrong huonx一ong huonlluq{电容换相换流器(eapacitor。ommutatedeonverters,CCC)在常规换流器的交流侧申人电容器构成换相电路的换流器。电容器一般申接在换流桥和换流变压器之间(如图1所示)。电容换相换流器可以减少换流器的无功消耗,且无功消耗基本不随直流输送有功的变化而变化,减少了换流站无功补偿设备和相应的投切开关;可以显著提高交直流系统运行的稳定性,增加抗扰动能力,减少换相失败的机率,对于连接弱交流系统其作用更加明显,还可以抑制换流阀的短路电流。由于电容参加换相,使阀尖峰电压和谐波有所增加。┌──┬──┐│5 12│凡32│├──┤ ││ │ │├──┼──┤│542 │562 │└──┴──┘ 图1电容换相换流器原理图 无功平衡在常规换流器中,换流器消耗的无功随直流输送有功的变化而变化。当直流输送额定功率时,换流器无功的消耗近似于输送有功的一半。这需要安装相应的无功补偿设备并通过不断投切无功补偿分组来保持换流母线的电压水平以及与交流系统的无功交换量,见图2(a)。无功补偿装置投切时,对交流系统产生扰动;当直流系统因故障停运时,会在换流站交流母线上产生较高的暂时过电压。 口‘p、呈之!一丝塑生乙限流器不平衡t ()叨川,) 瓜、亏:乍 ()图2人犯《P .uj滤波器为印.u》常规换流器和电容换相换流器的无功消耗(a)常规换流界,(b)电容换相换流器采用电容换相换流器后,换流站无功补偿容t可降至小于输送有功功率的15%,并且当直流抽送功率发生变化时,换流器消耗的无功变化缓慢,不偏要安装随有功变化而投切的无功补偿装皿,见图2(b).通过适当选择申联电容的容量,可以使所需的无功由几组高性能、低容量的交流滤波器来补偿,如采用连续可调交流滤波器(见换流站连续可调交流滤波装里). 动态德定性能电容换相换流器可以明显改善直流输电的动态稳定性能.电容器的申人直接影响了换相电压,使逆变侧的定关断角运行特性成为正斜率直线。而常规换流器的运行特性为负斜率直线,它和整流侧最小口角特性的交点不是一个稳定运行点(见直流堵电系统运行特性)。而电容换相换流器不存在不稳定工作点,特别是当逆变侧为弱交流系统时,其稳定性显著优于常规换流器。 在电容换相换流器中,除了交流母线电压以外,电容器提供了一个附加的换相电压。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。