说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 激磁涌流
1)  field inrush current
激磁涌流
1.
The dynamic voltage restorer (DVR) faces injection transformer risks generating field inrush current because of the over-saturation of the transformer.
然而,注入变压器铁心磁通会因为补偿注入电压初始相角的不同,在很大范围内变化,可能造成注入变压器的过度饱和,不但产生极大的激磁涌流、引起注入补偿电压的畸变,对变压器、逆变器的安全运行造成威胁,还会大大增加继电保护误动作的可能性,降低供电可靠性。
2)  Torrents poured down.
激流涌注。
3)  inrush current
励磁涌流
1.
A new method to identify inrush current based on the principle of dead angle;
基于波形间断角原理识别变压器励磁涌流的新方法
2.
Research on identifying inrush current of transformer based on the sine principle of current waveforms and the fuzzy degree nearness;
基于波形正弦特征和模糊贴近度原理的变压器励磁涌流识别方案研究
3.
New algorithm for judging transformer inrush current based on asymmetry elliptical model of flux and current;
基于磁通和电流不对称椭圆模型的变压器励磁涌流判别新算法
4)  Excitation inrush current
励磁涌流
1.
Method on the discrimination between excitation inrush current and fault current of transform based on wavelet analysis;
基于小波分析的变压器励磁涌流和故障电流识别方法
2.
Controlling strategy to restrain excitation inrush current of transformer based on its cause;
基于变压器励磁涌流成因的涌流抑制策略
3.
A new scheme for distinguishing transformer excitation inrush current based on wavelet analysis
一种新的基于小波分析的变压器励磁涌流判别方法
5)  magnetizing inrush current
励磁涌流
1.
Application of new techniques in magnetizing inrush current identification for transformer differential protection;
新技术手段在变压器差动保护励磁涌流识别中应用研究的现状
2.
Identification of magnetizing inrush current of power transformers based on features of flux locus;
利用磁通轨迹特征识别变压器励磁涌流
3.
Study on microcomputer differential protection device with magnetizing inrush current latching for transformers;
励磁涌流闭锁的变压器微机差动保护装置的研究
6)  magnetizing inrush
励磁涌流
1.
Identification of transformer magnetizing inrush based on equivalent instantaneous inductance in nonsaturation zone;
基于非饱和区等效瞬时电感的变压器励磁涌流鉴别方法
2.
A new wavelet transform approach to discriminate magnetizing inrush current and fault current;
小波变换识别变压器励磁涌流和故障电流的新方法
3.
Use fuzzy neural network to discriminate transformer magnetizing inrush and internal faults;
运用模糊神经网络来区分变压器励磁涌流和内部故障
补充资料:变压器涌流
      空载变压器刚接上电源时,电源侧出现的很大电流,其值可高达额定电流的6~8倍。涌流产生的原因是变压器铁心磁化曲线的非线性。如果铁心的磁化曲线如图中a所示,电源侧接入正弦电压u,按照磁化曲线Φ-i的关系,就可作出涌流波形i(图b)。涌流的波形和其幅值的大小,不仅与磁化曲线有关,而且与铁心剩磁磁通ΦR和电压投入时的相位均有关系。剩磁ΦR的存在,使铁心中的饱和磁通增大,导致励磁电流进一步上升。在电压投入相位为0°时,涌流值最大。图中标出的只是一个周期内的涌流波形,实际涌流是一种暂态电流,时间上是连续的。由于绕组存在电阻,随着时间的推移,波形的辐值会逐渐减小。涌流波形开始时偏在时间轴的一侧,然后逐步进入稳态,即电流与时间值逐渐对称,最后变成幅值很小而与时间值完全对称的正常的励磁电流,与电压相位差90°。
  
  三相变压器中,涌流在每一相中均可能出现。涌流是非正弦波形,含有许多谐波分量,其中以直流、二次和三次谐波分量占的比重较大。这些谐波的影响需加以抑制。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条