说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 直流分量法
1)  DC component method
直流分量法
1.
Then, it introduces a new integrated monitoring method consisting of the DC component method, AC superimoposition method and loss current measurement method, including the construction, key technology and technical paths of the on-line monitoring system.
本文首先介绍了交联聚乙烯绝缘电力电缆各种检测方法 ,然后详细介绍了由“直流分量法”、“交流叠加法”和“损耗电流测量法”三者结合起来的综合判断方法 ,其中包括在线测量系统的构成、关键技术、技术路线等。
2.
In this paper,a comprehensive method combined by DC component method , AC superposition method and loss current measurement method are described at first .
首先介绍了由“直流分量法”、“交流叠加法”和“损耗电流测量法”三者结合起来的综合判断方法,然后重点论述了交流叠加法的具体实现方案。
2)  DC component
直流分量
1.
Effects of water trees on insulation resistance and DC component of XLPE cable;
水树对XLPE电缆绝缘电阻与直流分量的影响
2.
It includes two parts: (A) the transient recovery voltages after circuit breakers interrupt the short-circuit currents or the current is out of phase condition;(B) the time constant of DC component of short-circuit currents and current-zero offset.
结合1000kV特高压试验示范工程及规划的中国特高压电网,研究了交流1100kV断路器瞬态问题中的短路电流直流分量衰减时间常数及交流电流过零点的漂移现象,在此基础上提出了我国交流1100kV特高压断路器的工作条件建议,如特髙压断路器试验的短路电流直流分量衰减的时间常数等。
3.
In the light of the DC components existing in active filters(APFs) based on one-cycle control(OCC), the OCC and its various improvement approaches are presented.
针对基于单周控制的有源电力滤波器存在的直流分量问题,介绍了单周控制及其各种改进方法,说明了引入纹波法、双环控制、双向互补策略、单极调制和双边积分控制在单相有源电力滤波器中的应用情况,并根据级数收敛判据对上述单周控制策略的稳定性进行分析比较。
3)  DC components
直流分量
1.
A new algorithm for blind watermarking based on DC components of DCT;
一种基于DCT域直流分量的盲水印算法
2.
The algorithm selects adaptively the embedding intensity to embed the watermark bits by modifying some AC components and DC components via the human visual system model and local characteristics of image,synthetically making use of the advantage of the AC components and DC components.
该算法利用视觉系统HVS特性和图像的局部特点,自适应地选择嵌入强度对载体图像各个分块的部分低频系数和直流系数嵌入水印,综合了交流分量和直流分量的嵌入优势,使水印的稳健性和不可见性达到较好的平衡。
4)  DC off-set
直流分量
1.
The analysis of the whole region stability condition and the mechanism of the DC off-set in the compensated current of the system is proposed.
分析了系统的全局稳定条件和补偿后电流中直流分量的产生机理,研究了系统带不平衡负载和动、稳态补偿性能以及稳定性。
2.
There are DC off-sets in the compensated source current of the APF with one-cycle control under bipolar modulation.
采用双极调制方式单周控制APF补偿后的电源电流中存在直流分量。
3.
There are DC off-sets in the compensated source current of the traditional APF with one-cycle control due to the existent ripple and the peak current detection.
传统的单周期控制有源电力滤波器以峰值电流检测的控制方式和纹波电流的存在导致补偿后的电源电流中含有直流分量。
5)  direct current component
直流分量
1.
A protection algorithm can be judged as having strong capability of anti-interference if it can eliminate decaying direct current component and high harmonic whose frequency is not the integer times of system base-frequency.
能否滤除非系统频率整数倍的谐波和衰减的直流分量是衡量保护算法抗干扰能力的重要特征。
2.
The article analyses the transient state of the unbalanced three-phase circuit on industial frequency and puts forward the concept that there are two direct current components with different attenuation coefficients.
分析了三相工频不平衡电路的暂态过程,提出了电流的直流分量中存在两个衰减系数不同的直流分量的概念。
6)  DC offset
直流分量
1.
In this paper, a method of precise evaluation on the amplitude, frequency, phase, DC offset and total distortion of sine wave series is introduced, that is the least mean square curve\|fitting and digital filtering.
介绍了精确评价正弦波序列的幅度、频率、相位、直流分量和失真度几个参数的一种方法 ,使用的手段是曲线拟合与数字滤波 ,并讨论了其拟合误差情况。
2.
In this paper,a method of precise evaluation on the amplitude,frequency,phase,DC offset and total distortion of sine wave series is introduced,that is the least mean square curve-fitting and digital filtering.
介绍了精确评价正弦波序列的幅度、频率、相位、直流分量和失真度几个参数的一种方法,使用的手段是曲线拟合与数字滤波,并讨论了其拟合误差情况。
补充资料:对称分量法
      电工中分析对称系统不对称运行状态的一种基本方法。电力系统中的发电机、变压器、电抗器、电动机等都是三相对称元件,经过充分换位的输电线基本上也是三相对称的。对于这种三相对称系统的分析计算可以方便地用单相电路的方法求解。
  
  电力系统的故障很多是三相不对称的。不对称故障下的电力系统将出现不对称的运行状态,三相的电压、电流等电量将是不对称的。但是只要三相系统各组成元件是对称的,那么在此系统中发生各种不对称故障时,仍可应用单相电路方法求解。办法是将三相不对称的电气量妑a、妑b和妑c分别用3组对称分量妑a1、妑a2、妑a0、妑b1、妑b2、妑b0和妑c1、妑c2、妑c0来表示,而妑1(妑a1b1c1)、妑2(妑a2b2c2)和 妑0( 妑a0b0c0)分别称为正序、负序和零序分量,它们之间的互换关系为式中 不难看出,本来不对称的三相电气量妑a、妑b、妑s已被3个对称分量妑a1、妑a2、妑a0替代,而作为正序分量的妑a1、妑b1、妑c1和负序分量的妑a2、妑b2、妑c2均为三相对称系统,零序分量妑a0、妑b0、妑c0则为三相相同的量。
  
  当三相系统仅在故障点是不对称的,其余部分均三相对称,则故障点的对称分量各序电流与各序电压之间存在下述简单关系:式中夦a1、夦a2、夦a0、夒a1、夒a2、夒a0分别为不对称故障点的各序电压、电流分量;夌a∑为系统α 相电源等效电动势;Z1∑、Z2∑、Z0∑分别为从故障点观察到的系统各序总阻抗。
  
  电力系统分别用上述三序阻抗及电源电动势组成该系统的正序、负序、零序网络,简称序网(见图)。图中因发电机只有正序电动势,故负序零序序网中没有电动势;N1、N2、N0为3个序网的始点;K1、K2、K0为3个序网的终点,即系统的故障点。
  
  不同的短路或断线故障,在故障点有不同的边界条件。根据故障的边界条件,可以将3个序网联接成一个分析故障电量的等效电路。这个等效电路称为复合序网。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条