1)  Inverter control
逆变站控制
2)  inverting
逆变
1.
This paper analyses the rationale and the design of the inverting MAG welding machine using the peak current mode control.
分析了峰值电流控制模式的基本原理和设计需要解决的问题 ,研究了峰值电流型控制模式IGBT逆变MAG焊机的一些设计要点 ,包括斜坡电流的检测、波形处理、斜坡补偿、轻载问题的解决和过流保护电路的设
2.
The principle of voltage soft-switch inverting, the method of measuring welding current by magnetic-loop and their advantages are discussed.
介绍了采用IGBT作为开关元件的弧焊逆变器,论述了电压软开关逆变原理、弧焊电流磁环检测方法以及其优点,介绍了电流调节器的应用。
3.
The circuit is fit for the PWM rectifying and inverting situation at which the power should flow in two direction.
该电路特别适合于能量需双向流动的PWM整流和逆变场合。
3)  invert
逆变
1.
Design of digital inverter for submerged arc welding;
数字化逆变埋弧焊电源的设计
2.
Parameter design for main circuit of soft switch invert welding power source;
软开关逆变式弧焊电源主回路参数设计
3.
A Review of the Application of Invert Technology to the Resistance Spot Welding;
逆变技术在电阻焊中应用研究
4)  inverter
逆变
1.
Improvement of the switch frequency and the material-decrease for spot welding inverter power;
提高逆变点焊电源开关频率与节材
2.
Medelling and simulation of resistance spot welding inverter;
电阻焊逆变电源的simulink建模及仿真
3.
MAG/CO_2 inverter welding power with complete remote control;
具有全遥控功能的逆变MAG/CO_2焊机
5)  inversion
逆变
1.
In order to improve the power parameter further,the intermediate frequency inversion of an electric voltage power type series resonance and frequency trace technique are adopted.
为使系统的功率因数较高,采用电压源型负载串联谐振中频逆变器和频率跟踪技术。
2.
A new current control resistance welder with inversion is designed.
设计了一种新型的电流型控制的逆变点焊机。
3.
In addition,the paper introduces the functions of inversion circuit and the working model of controlling and charging.
KA3525是PWM控制器件,利用其输出方波脉冲激励逆变器推挽电路的工作原理,使输出功率器件工作在开关状态,从而达到高效的目的。
6)  contravariant
逆变
1.
Exporation on New Type Contravariant Technology Used in Minorsignal Amplification;
新型逆变技术实现小信号放大的探索
2.
The paper briefly explains the contravariant principle and the effect of the return of afterflow,suggests the method of rendering the return of afterflow.
简要地说明逆变原理及续流回路的作用,提出了绘制续流回路的方法。
参考词条
补充资料:换流站逆变侧交流系统故障


换流站逆变侧交流系统故障
AC system faults on inverter side of converer station

  huanl一uZhonn{b一oneeJ一00!旧xltong guZhong换流站逆变侧交流系统故阵(AC systemfaults on inverter side of eonverter station)直流抽电受端交流系统发生的故障,包括三相短路、两相短路、两相对地短路、单相对地短路以及断线等.在常规的直流物电系统中,逆变器必须在受端交流系统提供的换相电压支持下才能正常工作。交流电网的故障会使逆变站交流母线电压的幅值、相位和波形发生变化,这些变化将可能引起逆变侧控制系统失去同步基准信号、阀触发系统储能不足,或逆变器的换相失败(见换流莽故降).逆变侧交流系统故障对直流系统的形响比整流侧的严重,其形响的程度往往以是否引发逆变器的换相失败或换相失败后是否能自行恢复正常来衡t。 三相对称故瘫,将由于故障地点的远近不同而使换相母线电压的下降程度不同,通常下降至额定电压的70%~60%时,逆变器就可能发生换相失败。由换相电流关系式可推导出三相交流电压下降造成逆变器发生换相失败的极限下降系数,即护万v[eos下。一eos(7。一y。。+600)〕式中。岛为换相电抗;几为直流运行电流,y。为关断角整定值;ym.二为极限关断角;U为故障前交流母线线电压有效值。如果采用低压限流(VDCL)的措施.通常在额定电压的40%时,还可维持直流系统运行。 交流系统不对称故障会使逆变站交流母线各相电压幅值和相位发生不同程度的变化。不对称故障除了降低换相电压外,还引起换相电压过零点的不对称移动,从而又直接影响到换流阀的关断角。通常不对称故障对关断角的影响比对称故障更严重。当逆变侧交流系统发生不对称故障时,逆变器往往会由于关断角变小而发生换相失败。
  
说明:补充资料仅用于学习参考,请勿用于其它任何用途。