说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 发电厂用电系统
1)  electric auxiliary system of power plant
发电厂用电系统
2)  station auxiliary power system
发电厂厂用电系统
3)  electric auxiliary system
厂用电系统
1.
The electric auxiliary system usually consists of condenser motor loads,and the starting of inductor motors can cause the problem of bus voltage fluctuations.
厂用电系统中一般带有集中电动机负荷,异步电动机启动会引起母线电压严重的波动。
2.
Through the power flow calculation and theoretical analysis for the electric auxiliary system using reactive power compensation,the economics benefit of the power plant was diseussed,and proved the project is feasible.
通过对发电厂的厂用电系统加入无功补偿后简单的潮流计算和理论分析 ,论述了在提高发电厂经济效益方面的作用 ,证明无功补偿方案的可行性。
3.
The electric auxiliary system sometimes has condenser motor loads,and the sta.
厂用电系统中一般带有集中电动机负荷,异步电动机启动会引起母线电压严重的波动。
4)  station service system
厂用电系统
1.
Improvement on treatment of single-phase earth faults in 6 kV station service system;
6kV厂用电系统单相接地故障处理方法的改进
2.
Novel neutral point treatment for power station service system;
发电厂厂用电系统中性点接地的新方法
3.
The main protection scheme of longitudinal differential relays collocated in the station service system,including high- voltage station transformer,series reactor,bus,short-distance transmission line,high-voltage alternating motor,etc.
论述了厂用电系统中高压厂用变压器、串联电抗器、母线、短引线、高压交流电动机等电力设 备配置纵联电流差动继电器作为主保护的方案,指出了各设备和对应的差动配置方案的特点、应用 中存在的特殊问题和整定计算中的影响因素,推荐了整定值。
5)  auxiliary supply system
厂用电系统
1.
This paper illustrates kinds of automatic transfer mode in auxiliary supply system, and explains the whole transfer period in detail, then concludes the importance and necessity of selecting high speed transfer in auxiliary supply system.
详细阐述了厂用电系统的各种切换模式及对切换全过程进行了细致的分析,通过比较,阐述了快速切换在厂用电系统切换中的必要性。
2.
In station, neutral grounding modes of high voltage auxiliary supply system have isolated neutral、 grounding by resistance and grounding by arc- suppression coil, each mode has different excellence and defect.
发电厂高压厂用电系统中性点接地方式有不接地、经消弧线圈接地和经电阻接地等,各种方式各有其优缺点。
6)  auxiliary power
厂用电系统
1.
Through analysis on the ferromagnetic resonance phenomenon in auxiliary power system of the nuclear power station, the possibility of the circuit resonance of the generator voltage is discussed.
通过发生在核电站厂用电系统的一起铁磁谐振现象的分析和处理,探讨了防治措施和方法。
2.
Two misoperations may cause generator energization fault:the improper close of generator -transformer circuit breaker and that of auxiliary power transformer branch circuit breaker.
发电机误上电故障有2种发生形式:一种是由发电机组的主开关误合闸引起,另一种是由厂用电系统开关误合闸引起。
补充资料:厂用电系统


厂用电系统
station auxiliary power system

Chongyongd.on xltong厂用电系统(station auxiliary power system) 为火力发电厂辅助设备的动力、控制、调节、照明、设备检修等的用电而设里的厂内供电网络和厂用配电装t、厂用电源等所构成的总体。其任务是保证发电厂连续安全满载运行,满足机组起动、正常运行和停机等工况下供电的需要。根据电厂安全运行要求,厂用电系统设置有监视、控制、保护和连锁等自动装里。 设计要求厂用电系统应做到:①各机组的厂用电系统各自独立,当一台机组故障停运或其辅机的电气设备故障时,不至影响另一台机组的正常运行,并能在短时间内使本机组恢复运行;②配备可靠的备用(或起动/备用)电源,接线简单,在工作电源故障时能可靠投人,在起停过程中便于切换操作,并能与工作电源短时并列;③考虑电厂分期建设和连续施工过程中厂用电系统的运行方便,对公用负荷的供电要合理安排,便于过渡,尽可能减少改变接线和更换设备;④200MW及以上机组设置交流事故保安电源,在全厂停电时能够快速起动投人,向保安负荷供电。同时要设里交流不停电电源,保证计算机和自动装置等不间断运行。 组成厂用电系统由厂用电源、配电装置(母线和开关设备等)、厂用负荷和馈线等组成。厂用电系统分高压厂用电系统(国际上称中压厂用电系统)和低压厂用电系统,前者电压为3~10 kV,后者为380/22oV、 厂用电源厂用电系统对安全供电有较高的要求,必须设里可靠的工作电源和备用电源。重要负荷应有两个独立的供电电源,正常情况由工作电源向厂用负荷供电.工作电源故障退出运行时,备用电源自动投人。现代火力发电厂厂用工作电源均由发电机通过厂用工作变压器或发电机提供,厂用备用电源通过备用变压器或电抗器由电力系统提供。当小容量发电厂有发电机电压母线时,厂用工作电源由各段母线引接。200MW及以上的机组设置快速起动的柴油发电机组作为交流事故保安电源,交流不停电电源则采用静态逆变装t。 厂用电母线高、低压厂用电母线一般多采用单母线按炉分段,母线段数的设置与机组容量有关,中、小机组每炉设1~2段,大型机组每炉设2一4段,当公用负荷较多、容量较大时,设公用段。配电装!多采用成套配电装!,内设断路器、熔断器、接触器、电流互感器、电压互感器等电器,用于正常关合和事故时负荷的切除。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条