1)  flame failure device
熄火保护装置
2)  full-automatic cut-off protection
全自动熄火保护装置
3)  extinction
熄火
1.
The assumption of unity Lewis number in the flamelet model of turbulent combustion is examined and the influence of differential diffusion and radiation on the flamelet structure, nitric oxide emission and extinction limit is investigated.
对拉伸层流扩散火焰面进行了数值模拟,考察了在以往湍流燃烧的火焰面模型中,假定Lewis数等于1的可靠性,研究了不同分子扩散和火焰辐射对火焰面结构、氮氧化物排放和熄火临界的影响。
2.
In a pilot scale reverse flow reactor with a liter of catalyst, catalytic combustion of typical industrial waste gas contaminated with volatile aromatic compounds (VOC) was systematically investigated, and the "temperature run-away"in the case of too high feed concentration and the "extinction of reactor" in the case of low feed concentration were observed.
在流向变换催化燃烧小型中试装置上利用国产催化剂进行了含混合芳烃模拟工业废气的净化试验 ,重点考察了挥发性有机物 (VOCs)能够通过调整换向周期在既不“飞温”也不“熄火”的条件下保持很高的VOCs转化率的浓度变化范围 ,初步观察了由于VOCs浓度过高或过低所引起的“飞温”或“熄火”过
3.
Using the digital image processing technique and the laser tomography technique, a novel approach based on the turbulent intermittence was proposed here to describe the extinction process of turbulent flame.
对模型与试验中获得的临界熄火现象进行了对比 ,结果令人满意 。
4)  extinguishment
熄火
1.
The quenched samples of GAP/AN propellant after combustion extinguishment were obtained by a new quenching method.
采用一种新的方法得到中止燃烧以后的熄火样品 ,利用扫描电子显微镜和能谱分析研究了 GAP/AN推进剂熄火表面的结构和形貌。
2.
Only in this year,extinguishment has occurred several times,especially for a DG 670/140-8 boiler, DCS data recorded showed some phenomena not encountered before when it extinguished.
镇海发电厂一台DG 670/140-8锅炉在2005年7月12日发生的一次熄火事故,指出原因在于煤种与炉型的严重不匹配,造成2号角上一次风管内发生爆燃,并产生一次风管堵管的假象。
5)  misfire
熄火
1.
Simple harmonic analysis is carried out for the excitation torque when a single-cylinder misfired.
利用系统矩阵法求解了发动机曲轴扭振系统的强迫振动特性,并对发动机单缸熄火时扭振系统的激励力矩进行了简谐分析。
2.
The method with rotation velocity of single cylinder misfire is presented in this paper to measure diesel engine cylinders work evenness.
提出了简单实用的单缸熄火转速法 ,用以测量柴油机各缸工作均匀性 ,并进行了实验研究。
6)  flameout
熄火
1.
Problems and solutions for frequent flameout of HG-1025/18.2-YM6 boiler;
HG-1025/18.2-YM6型锅炉频繁熄火问题分析
2.
This paper is to solve the flameout problem of a boiler.
针对某厂11号炉接连发生多次正压熄火现象,在锅炉冷态通风条件下,将燃烧器的一次风、内外二次风和增压风分别调匀,通过测试燃烧器回流区,确定内二次风挡板开度的合适范围。
3.
Presents a torsional vibration model during the flameout of a cylinder with the system matrix method.
利用系统矩阵法建立了车辆动力传动系在发动机一缸熄火时的扭振数学模型。
参考词条
补充资料:串联电容补偿装置保护


串联电容补偿装置保护
Series capacitor/compensator protection

不装设MOV,只靠旁路间隙进行过电压保护,当线路故障电容器组两端的电压超过规定值时,旁路间隙放电,保护电容器组不受损害.其优点是节省投资便于扩建,缺点是区外故津后电容器组的再接入时间长。 电容器过负荷保护通常装在一相上。当过负荷的电流与持续时间超过电容器的额定过负荷能力时,保护动作使旁路断路器合上,将电容器退出. 电容器内部故障保护包括内部元件保护和桥式差动保护。电容器内部元件保护由装在外壳内每个元件上的单独熔丝构成,元件击穿时熔丝熔断将故障元件隔离。桥式差动保护由装在两申电容器中部连线上的电流互感器或传感器(见今联电容补偿装l中的图1)以及相应的继电保护组成,正常时连线两端电位平衡,无电流通过,当某些电容器元件击穿、熔丝熔断后,两端电压不平衡,保护动作.当不平衡程度较轻,电容器上的过电压不超过额定电压10%时,桥式差动保护一般只发信号;当击穿元件多、不平衡严重、电容器上的过电压超过额定电压10%时,桥式差动保护合上旁路断路器,将电容器退出。 金属氛化物限压器保护包括过载保护及损坏保护。过载保护一般由MOV电流、能t和温度测量等元件组成,当MOV过载时一般触发旁路间隙使其放电然后合上旁路开关,经过一段时间后,根据运行要求,再断开旁路开关将申联电容器再接人系统。当MOV保护装t监测到的MOV电流持续超过正常水平,或MOV电阻低于正常水平,就认为 MOV损坏,保护装t将旁路断路器快速闭合,申补电容退出运行。 旁路间隙保护一旦旁路间隙导通,旁路断路器随之将其暂时短接,当旁路间隙的绝缘强度恢复后或MOV经散热,热容t恢复后,根据运行要求旁路断路器可断开,申补装工重新投人运行。 旁路断路器故障保护一般旁路断路器都装有备用的合阿线圈以防合闸失灵。万一无法合闸,就将命令送至线路断路器,将线路断路器跳开,或者同时命令旁路筋离刀闸合上。 次同步谐振保护由对次谐波电流敏感的继电保护装t或模块组成。当发生次谐波谐振时.次谐波保护动作,合上旁路断路器,将电容器退出. 平台故库保护当申联电容补偿装置的任何一点对平台击穿或闪络时,该保护动作使旁路断路器合闸,将申联电容退出运行。平台上下通常用光纤来传递保护和控制信号。