说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 零序阻性电流
1)  zero-sequence resistance current
零序阻性电流
2)  zero-sequence resistance
零序电阻
1.
Based on separate setting of zero-sequence reactance and zero-sequence resistance compensation coefficient in protection device,an algorithm and a mathematical model of zero-sequence compensation coefficient are proposed.
基于保护装置由零序电抗和零序电阻补偿系数提出一种零序补偿系数整定算法,建立了几种运行方式下零序电抗和零序电阻补偿系数的数学模型,并通过算例对几种运行方式进行详细比较,结果表明,该算法能正确地为零序补偿系数整定提供依据。
3)  zero-sequence current in neutral-point
中性点零序电流
4)  zero sequence current
零序电流
1.
The paper Presents the principle of selective leakage protection based on zero sequence current direction.
文中阐述了基于零序电流方向选择性漏电保护的工作原理,介绍了以单片机80C196KB为核心,通过相敏整流的方法来判断零序电流方向的实施方案,具有抗干扰性能好,实施电路简单的优点。
2.
This paper analyzes the basic principle of Sel587 differential protection device and elaborates the influence of zero sequence current .
分析SEL587差动保护装置的基本原理,阐述零序电流的影响。
3.
In order to reduce influences of varieties of operation conditions of power systems and differences of grounded fault type on the protecting range of the instantaneous zero sequence current protections of transmission lines,a feasible method for realizing the adaptive instantaneous zero sequence current protections was put forward.
为了尽可能减小线路零序电流速断保护的保护范围受系统运行方式变化等因素的影响,提出了一种自适应零序电流速断保护的实现方法。
5)  zero-sequence current
零序电流
1.
Comparative analysis on zero-sequence current of Y,y_(no) and D,y_(n11) transformers;
Y,y_(n0)型与D,y_(n11)型配电变压器零序电流比较分析
2.
Analysis of transient process of zero-sequence current during single-phase reclosure;
单相重合闸过程中的零序电流暂态过程分析
3.
Polarity check of zero-sequence current and voltage based on microcomputer protection;
基于微机保护的零序电压与零序电流的极性判定
6)  zero order current
零序电流
1.
Starting with the traits of zero order impedance and the relationship between zero order current and zero order impedance,analyzes the main differences of electric traits of power cables and aerial lines and the disadvantages of applying power cables into the traditional grounded protection.
从正、负、零序阻抗特性以及零序阻抗与零序电流的关系入手,分析了架空线路与电力电缆电气特性的主要区别及传统接地保护应用于电力电缆线路所带来的弊端。
2.
On the basis of analyzing the law of variation of the zero order current, the zero order voltage and the zero order power in the isolated neutral system, a synthetic criteria principle of selecting the grounded fault line according to three criterias at the same time was put forward.
在对中性点不接地系统单相接地故障情况下零序电流、零序电压以及零序功率的变化规律做了认真分析的基础上,提出了采用3个判据同时判断的故障选线三合一综合判据原理,这个综合判据可以大大提高接地选线的准确率,具有一定的推广利用价值。
补充资料:零阻电流法测电偶电流
分子式:
CAS号:

性质:测定电偶对之间电阻为零的条件下所流过的电偶电流的方法。最先进的是自动零电阻电流计法,其原理是用一个运算放大器的同相和反相输入端分别接电偶对的两个金属,放大器输出端通过已知阻值的电阻反馈至反相输入端。运算放大器会自动调节两个金属之间电位差为零。流经反馈电阻上的电流即电偶电流,可通过反馈电阻上的电压降(即运算放大器的输出电压)来测定。该法灵敏、快速。

说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条