说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 畸变和负序电流
1)  distorted and negative sequence current
畸变和负序电流
2)  current distortion
电流畸变
1.
The reason of input current distortion under an unbalanced input voltage was demonstrated.
结果表明:改进的策略同样适用于输入电压平衡的情况;与经典策略相比,在相同的电压不平衡条件下,改进的调制策略可使输入电流畸变率(THD)减小2%~3%;改进的策略只有在输入电压能够保证输出电压达到期望输出值的条件下才能有效减小输入电流的畸变。
2.
By an appro- ximate method of harmonic calculation, the guidelines for the design of the power filter are then preserted, considering the effects of current distortion and power factor.
本文提出了一种适用于逆变器上的功率滤波器,并用谐波计算法,从电流畸变、功率因数的观点分析了该滤波器参数设计准则。
3.
When average current control method is applied to the single-phase dc side series active power filter, the input current distortion is serious during low frequency switch turns on or turns off transient.
另外在低频开关切换点后附近,电感电流上升(下降)斜率几乎为零,这也造成了实际电流会在一段时间内跟踪不上参考电流,引起输入电流畸变。
3)  distorted current
畸变电流
1.
Method of observing distorted current (or voltage) based on instantaneous power theory;
基于瞬时功率理论的畸变电流(或电压)观测方法
2.
It makes use of some characteristics of triangle functions, and calculates the amplitudes of the fundamental active and the reactive current components in distorted current.
它利用三角函数的有关特性 ,对畸变电流中的基波有功和无功电流分量的振幅分别进行计算 ,然后通过低通滤波器把它们分离出来 ,最后得到基波有功和无功电流分量。
4)  distortion current
畸变电流
1.
The distortion current detecting circuit is an important part of active power filter that determines its compensating characters.
有源电力滤波器是用于对电力系统谐波、无功及负序电流进行动态综合补偿的装置,其中的畸变电流检测电路是决定补偿性能好坏的重要环节。
2.
A non-PLL ip-iq method of distortion current detection was raised so as to avoid offset error of phase due to PLL.
阐述了基于瞬时无功功率理论的ip-iq法基本原理,提出了一种无锁相环(PLL)的ip-iq畸变电流检测法,可以消除由于PLL而产生的相移偏差。
5)  negative sequence current
负序电流
1.
Design and application of generator negative sequence current monitoring instrument;
发电机负序电流监测仪的设计与实现
2.
Much more attention is paid to the analysis of the method how to define the characteristic curves of phase sensitive symmetrical short circuit protection, the design of negative sequence current filter and the definition of the mathematical model of overload.
重点介绍了对称短路相敏保护特性曲线的确定方法 ,设计了负序电流滤波器 ,建立了过负荷保护的数学模型 。
3.
Aiming to characteristic of 3-phase to 2-phase power supply based on balance transformer, a new current balance compensation method utilizing inverter is proposed, which is mainly used to compensate negative sequence current.
从而使平衡变压器两相侧的输出电流对称,消除平衡变压器三相侧产生负序电流的条件,达到三相电流对称的目的。
6)  negative current
负序电流
1.
Analysis of negative current in switching tests for load tap on-load tap-changers of transformers;
变压器有载分接开关切换试验中负序电流分析
2.
Analysis of the operation of the generator negative current protection impacted on by the electric railway loading
电气化铁路负序电流对发电机负序过流保护的影响
3.
According to the frequency excursion in power systems, this paper proposes a detecting method of harmonic negative current instructions.
针对电网出现的频率偏差 ,提出一种谐波负序电流指令的检测方法。
补充资料:交流电气化铁路的负序电流和负序电压


交流电气化铁路的负序电流和负序电压
the negative sequence current and voltage produced by AC elec-tric railway

  处为最大,随着负序电流逐渐分散进人电力系统,系统各处的负序电压水平将逐渐下降。YN,d一l:v.v:单相平衡接线11:重臂负荷I]l=轻价负荷月=111/11两,负荷功率因教相同0。250。5751。0 图2不同接线牵引变电所的负序电流系数 允许标准不同类型发电机的负序承受能力不同,为此,首先应根据有关电机制造标准,选择允许的负序标准。在缺少电机制造标准规定时,可参照以下规定:当汽轮发电机在额定工况连续运行时,三相电流差不应超过10%,水轮发电机三相电流差不应超过20%;有关电力系统公共连接点的三相电压不平衡度,中国国家标准规定:“正常的电压不平衡度允许值为2%,短时不得超过4%”。 改善措施主要有: (1)对电气化铁路各牵引变电所实行进线相序轮换,减少电气化区段的综合负序。 (2)采用平衡接线变压器,常用的接线型式有斯科特、列布兰、变形伍德布里奇等方式。 (3)在受负序电流影响最大的电力系统分支回路中加装电抗器,以限制进人该支路的负序电流。i旧01一u dlanqihua tielu de fuxud一anl旧he fuxud一onya交流电气化铁路的负序电流和负序电压(thenegative Sequenee eurrent and voltage produeedby AC eleetrie railway)交流电气化铁路的单相牵引负荷会造成电力牵引变电所一次侧三相负荷电流不平衡,任一三相不平衡系统均可用对称分量法分解成正序、负序和零序三组对称分t的盈加,从而在电力系统中产生负序电流和负序电压.接人电力系统线电压间的单相负荷不产生零序分量,只有正序和负序分t。负序电流、负序电压的有害影响有: (l)可在同步发电机转子中产生附加损耗和局部发热,造成系统出力下降, (2)负序电流产生的负序转矩,使发电机振动,影响安全运行; (3)增大系统中各翰电环节的损耗; (4)负序电压的存在对系统中三相电动机用户产生不利影响,造成电动机三相电流不对称和附加损耗,使出力下降并危及电动机安全。 牵引变电所的负序电流电力牵引变电所负序电流取决于两供电臂负荷的相位和幅值,因此可以把牵引变电所看作是一个负序电流源. 图1示出变压器为YN,dll接线的三相牵引变电所在两份用电功率因数相同时的负序电流相盆图.图1的上方为臂电流和变压器二次绕组的三相电流相量;中间为正序电流相量;下方为负序电流相t.不同供电臂产生的负序电流有1200相位差。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条