1)  switching component
开关元器件
2)  on-off
“开-关”
3)  switch
开关
1.
Role of metal ionic compounds in fluorescent molecule switches;
金属离子络合物在荧光分子开关中的作用
2.
Research on driven system of switch magnetic resistance motor in mine electric locomotive;
矿用电机车开关磁阻电动机驱动系统的研究
3.
Research of model KZS-115 hydraulic reciprocating controlling switch;
KZS-115型液压往复式控制开关的研制
4)  switches
开关
1.
General-utility testing path model of switches for ATE and application;
通用ATE开关资源测试路径模型及应用
2.
The working principle and the functions of the monostability multivibrator composed of 555 timer are introduced in the paper,and the time switches are designed.
介绍了用555定时器构成的单稳态触发器的工作原理,对其功能作了进一步探讨,在此基础上设计了一种具有实用价值的定时-非定时两用开关。
3.
Three dimensional visualization is applied to low voltage switches that involve pre processing, calculation and analysis, and post processing.
从前处理、计算分析和后处理3个方面,介绍了低压开关操作机构三维可视化仿真技术。
5)  circuit breaker
开关
1.
5033 circuit breaker acting abnormally in the annual overhaul of Doushuang power line in Douli substation.
针对斗笠变电站500kV斗双线年检中5033开关动作异常情况进行了分析,找到了5033开关动作异常并导致开关保护屏中操作箱手合插件烧毁的原因,提出了应对措施。
2.
Several 500 kV circuit breaker failures and abnormal conditions since 500 kV Wanquan Substation was put into operation are listed and analyzed in this paper,and some measures to ensure safe and healthy operation of equipment is also proposed in view of equipment selection,installation& commissioning,acceptance,operation and maintenance.
列举了5 0 0 k V万全变电站自投运以来所发生的几起5 0 0 k V开关事故及异常,对事故及异常发生的原因进行了分析,并从设备的选型、安装调试、验收、运行、检修等方面提出了确保设备安全健康运行的措施。
3.
In this paper,the authors analyzes the main reason of the insulated pin fault,propose some suggestions and the key overhaul item about type LW6-220 circuit breakers.
通过对一起绝缘拉杆脱落故障的主要原因分析,提出了针对LW6型开关的重点检修改造项目,对防止高压开关发生非全相故障,保证电网的安全稳定运行具有积极的意义。
6)  breaker
开关
1.
Causes analysis about one point earthing leading to breaker tripping in DC system;
直流系统负极一点接地致开关跳闸原因分析
2.
Problems existing in malfunction protection during operation were analyzed,there are two problems in it,one is that one-phase re-switching might not work when the outlet breaker of malfunction protection instantaneous trip circuit is sprung,the other is that malfunction might be caused when malfunction protection outlet connects to TJP of phase separated box.
失灵保护存在两个问题:一是失灵保护瞬跳线路出口开关可能造成单相重合闸拒动;二是失灵保护出口接分相操作箱的永跳端子TJR时,可能造成误动。
3.
Pole-mounted SF6 breaker product is an electical apparatus widely applied in power supply and distribution net-works.
柱上SF_6开关产品是广泛应用于供配电网的电器。
参考词条
补充资料:真空开关器件
      利用真空间隙耐压高和真空电弧传导大电流特性完成通断功能的器件。
  
  真空开关器件出现于20世纪50年代。其基本结构是一个装有动电极、定电极和电弧屏蔽罩的高真空灭弧室。动电极包括动触头和动跑弧面两部分,定电极包括定触头和定跑弧面两部分,通常将两电极结构设计成具有径向磁吹特性。动电极借助金属波纹管与外部动导电杆相连,在交流电流导通期,在真空密封条件下可以任意操纵动、定电极的开合动作,以达到通断交流电路的目的。电极周围装有电弧屏蔽罩,用来凝集燃弧区中扩散出来的金属蒸气,以防管壁绝缘遭到破坏。真空间断器的结构见图。当真空间断器的两电极端面(触头)闭合在一起时,可传导正常的交流电流。当电路中出现故障电流时,动导电杆就将动电极拉离定电极,此时在电极表面局部受热的斑点中蒸发出金属蒸气,起燃真空电弧,随之进入大电流导通期,器件内真空电弧发展到大电流电弧期,电弧头部在电极表面跑弧面内移动;电弧则在两电极所拉离的间距中发展。交流电流达零值时,电极表面上受热斑点熄灭,真空电弧随即熄灭。残余金属蒸气和等离子体很快在电弧屏蔽罩和电极上冷凝和复合,真空间断器处于真空隔离状态,电路遂被切断。
  
  
  真空开关器件包括真空间断器、真空接触器、真空击穿器和真空负荷开关等。这类开关器件均有动作行程短、封闭电弧、通断性能好、维修率低、寿命长、体积小和重量轻等优点。真空开关器件在真空开关装置、高压传输装置、配电装置、装甲控制装置和马达起动装置中有较广泛应用。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。