说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 轴带异步发电机
1)  asynchronous shaft driven generator
轴带异步发电机
2)  induction generator
异步发电机
1.
Effect of excitation capacitance on transient voltage buildup in induction generators;
自激电容对异步发电机暂态建压过程的影响
2.
Terminal reactive compensation power of induction generator under constant voltage opeation;
异步发电机恒压运行时机端无功补偿功率
3.
An analysis approach based on eigenvalues of the state equation matrix is utilized to study the effect of the self-excited capacitances on the no-load transient voltage build-up and determine the minimum build-up capacitance of an induction generator.
为研究自激电容对异步发电机空载暂态建压过程的影响并确定最小建压电容值,采用了以状态方程矩阵特征值计算为基础的分析方法。
3)  asynchronous generator
异步发电机
1.
To ensure the secure operation of wind farms, according to the conversion character of wind power and operation performance of asynchronous generators a mathematical model for wind farm and related power gird under large disturbance is built, and the voltage stability of wind farm and related power grid is calculated while short-circuit fault occurs.
为保证风电场投入后的安全,按大干扰下风功率的转换特性及异步发电机的运行特性建立了风电场与相关电网的数学模型,计算了风电场与相关电网发生短路故障后的电压稳定性。
2.
Based on the steady-state equivalent circuit of the asynchronous generator,the study was carried out through dynamic changes of the reactive power of the wind farm and with consideration of the wind velocity,active power,generator-end voltage,and the sliding-rolling ratio.
潮流计算是分析风电对电网影响的基础,在异步发电机稳态等效电路的基础上,通过动态改变风电场的无功功率、考虑风速、有功功率,机端电压和滑差率,提出了计算含风电场的电力系统潮流的一种简单可行的方法,并通过一含风电的配电网系统验证了该算法的可行性。
3.
The paper introduces the steady model of wind turbines with an asynchronous generator.
介绍了异步风力发电机组的稳态模型,在传统RX模型的基础上,将风力机吸收的机械功率与发电机的电功率之间的差值、异步发电机的滑差引入牛顿迭代法的修正方程,形成扩展修正方程,从而避免了传统RX模型算法实现中的2个迭代过程,使牛顿迭代法仍具有平方收敛。
4)  shaft generator
轴带发电机
1.
Static var generator application in marine shaft generator system;
静止无功发生器在船舶轴带发电机系统中的应用
2.
Protection to shaft generator in electrical design of 8000 t ro-ro ship;
8000t滚装船电气设计中的轴带发电机保护
3.
Research and Design for Parallel Inverter Modules of Shaft Generator;
轴带发电机逆变器并联的设计与研究
5)  bearingless induction motor
无轴承异步电机
1.
The air GAP field identification methods and application of bearingless induction motors;
无轴承异步电机气隙磁场辨识方法与应用
2.
Research on Nonlinear Decoupling Control of the Bearingless Induction Motor;
无轴承异步电机非线性解耦控制的研究
3.
Research on Speed Sensorless Technology for Bearingless Induction Motor;
无轴承异步电机无速度传感器技术的研究
6)  Asynchronous generator unit
异步发电机机组
补充资料:发电机失磁异步运行


发电机失磁异步运行
asynchronous operation of synchronous generator

fod旧nJ.shle一y一bLJ ytjrlx一r、口发电机失磁异步运行(asynChronous opera-tion of synehronous generator)同步发电机运行中突然失去励磁转人异步发电机运行的工况。 失磁异步运行原因发电机失磁大多是由于励磁系统和发电机转子绕组故障而引起。励磁系统故障通常有直流励磁机故障,静止和旋转半导体励磁系统的整流元件损坏,自动晶闸管励磁系统和副励磁机恒压部分故阵,励磁机断路器故降或非故障断开等。发电机转子烧组故津引起的失磁主要原因是转子绕组断线. 失滋异步运行的影响①对发电机的影响.发电机失磁后即进人异步运行工况,此工况对不同结构的发电机引起不同程度的转子过热、定子端部绕组和端部铁芯部件过热及发电机振动。对整体锻造的隐极式转子发电机,在较小的淆差下可以发出较大的异步功率,一般不会造成危害,故允许短时间异步运行(允许时间由制造厂或经试脸决定).对绑线式汽轮发电机(巳很少使用)和凸极式发电机,特别是有阻尼绕组的水轮发电机,则不允许异步运行。②对电力系统运行的影响。发电机失磁后不但不能发出无功功率而且还要从系统吸收无功功率。发电机失磁后在异步运行中所吸收的无功功率约与其倾定有功功率的数值相等,发电机失磁后系统中并列运行的其他发电机须多供出相当失磁发电机额定有功功率的数值约两倍的无功功率,才能维持原来系统无功电源的水平。否则系统局部电压要大幅度下降,甚至发展成电压崩溃。 失磁运行的对策①发电机组是否允许短时间失磁异步运行,应按同一类型机组的典型试验确定,应计算发电机失磁异步运行时的机端电压是否低于允许值.发电机组厂用电供电电压是否合适或能否自动切换到其他可靠电裸。如果同时满足以上条件,可以允许发电机组短时异步运行。这时,运行人员必须迅速采取措施恢复励磁(包括起用备用励磁机),同时将失磁发电机的有功负荷转移到正常运行的发电机上去。②其他情况下,应由发电机的失磁保护将发电机组从系统中断开。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条