说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 高接地电阻
1)  high earth-Connection re-sistance
高接地电阻
2)  grounding via high resistance
高电阻接地
3)  high-resistance grounding
高阻接地
1.
Aiming at high-resistance grounding faults,the operating characteristics of phase current differential protection and zero-sequence current differential protection are analyzed,and a conclusion is obtained that when high-resistance grounding,zero-sequence current differential protection is more sensitive than phase current differential protection.
针对高阻接地的特殊故障,仔细分析了分相电流差动保护和零序电流差动保护的动作特性,并得出结论:高阻接地时,零序差动比相电流差动更灵敏。
4)  grounding with high resistance
高阻接地
1.
Based on probability analysis,a new method of fault detection and location in distribution network grounding with high resistance is proposed in this paper.
针对配电网系统的单相高阻接地故障,提出了一种基于概率分析的故障检测与定位方法。
5)  high resistance grounding
高阻接地
1.
With comparing different methods of grounding and considering different factors, high resistance grounding was selected.
经过对各种接地方式的比较,综合考虑了各方面的因素之后,选择了高阻接地这一适合于船舶电力系统的接地方式。
2.
The design features of service power system in Huizhou Gas Turbine Power Plant are as follows:to adopt two-winding transformer for high voltage service power,the bus section for medium voltage service power is designed as one section;to adopt high resistance grounding for the neutral point of high voltage service power .
惠州燃机电厂厂用电系统的高压厂变选用双卷变压器、中压厂用母线段设计为一段、高压厂用电系统中性点采用高阻接地方式、不设高压公用母线、每台机组均设置一段交流保安电源,这种厂用电系统设计合理、操作维护方便。
3.
Taking the faults of high resistance grounding before and after the capacity expansion of Datong-Qinhuangdao Line,and starting from the introduction of current increment protection principles,this paper analyzes the problem of high resistance grounding in tractive power supply system,and probes into the significance of current increment protection.
以大秦线扩能改造前后发生的高阻接地故障为例,从介绍电流增量保护原理入手,分析了牵引供电系统高阻接地问题,探讨了电流增量保护的意义。
6)  high impedance grounding
高阻接地
1.
A new algorithm of fault allocation for high impedance grounding is presented,which is based on the math model of power line described by differential equation and uses the information of single terminal to allocate the fault of HV power transmission line.
提出了一种适用于高阻接地故障的故障测距新算法。
补充资料:电力系统中性点电阻器接地


电力系统中性点电阻器接地
resistance grounded of electric power system

d lanllx一tong zhongx一ngd旧nd旧nzuqll旧d-电力系统中性点电阻器接地(r esistancegrounded of ele亡trie power system)电力系统中至少有一个中性点接人电阻器与大地连接,目的是限制接地故障电流。中性点经电阻器接地可以直接消除不接地系统的两个严重缺点,即能减少弧光接地过电压的危险性,并使灵敏而有选择性的接地保护得以实现。另一方面,由于这种系统的接地电流比直接接地系统的小,对邻近通信线路的干扰也较弱。 单从降低弧光过电压角度来看,电阻器阻值凡满足Re、扁(。是系统的每相对地分布电容,就可以了.弧光接地时,在电弧点燃熄灭过程中,系统积累多余的电荷,使振荡过程加剧,从而产生很高的过电压。若能使这些电荷在从电弧熄灭到重燃前的一段时间(半个工频周期)内通过中性点电阻器泄漏掉,过电压就能降低。当R。)1。森时,电弧接地引起的瞬态过二““一’,。司’一七一‘一3创(,’J’一。夕阮~~J’~HJ~J即~程与中性点不接地系统没有多大区别,而当Re(今~切’一‘”、一’~~,、,“~「刁~/、~月J”,叼~一e~记试了时,过电压就小得多了。因为线路对地电容向R。放电遵循f“放电规律,当满足尺簇东时,放电时间常~v口“~~尹柑厅’司’门~‘.f~以了“砚’~毛”J「,甲数T一3R£一立一息,当‘为半个工频周期‘-钻‘一“’、叫。一2汀’闷’/JT’一州产,川’一弄时,线路上的电荷由1降至e一号一。.35。这说明Zf“切’城耳J-“;吧1”因几汗二“一二t,口“趋肠们电荷大部分(约2/3)泄漏掉,因而不会再产生很高的振荡过电压,在规模不大的架空线路系统中接人这种电阻器后,接地电流仍然不大,仍未破坏接地电弧自行熄灭的条件。这样,此种称为高值电阻器接地的系统就可以保持不接地系统(发生接地故障但不跳闸)的优点,同时又解决了弧光接地过电压的问题。 为了获得快速选择性继电保护所需的足够电流,就必须降低电阻器的电阻值。但电流越大,电阻器功率越大,设备将很笨重;同时电流太大,又将有与直接地系统类似的缺点。根据运行经验,一般采用接地故障电流入为100~1000A。阻值再小就不如用电扰器有效.有的国家是把If控制在变压器额定电流的水平。使用这种阻值较低的电阻器接地系统既消除了弧光接地过电压,又使不接地系统经常出现的由电磁式电压互感器引起的铁磁谐振不再发生。当系统规模较大,特别是有重要的用户时,因为这些用户常有备用线路.要求故障线路迅速切除,故可选用这种接地方式. 根据以上考虑的中性点电阻器接地系统都不是有效接地系统。这种系统中的变压器不能采用分级绝缘(即中性点需采用全绝缘)。 以上两种高值和较低值电阻器接地方式适用于不同情况的配电系统,它们具有不接地或直接接地方式的某些优点,也多少存在两种接地方式的某些缺点。 对于发电机中性点电阻器接地方式还有些特殊考虑.为了避免发电机在发生绕组接地故障时将铁芯烧坏,要求使单相接地电流减小到比loA更小。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条