1)  Get away
离开
1.
Otherwise, Get away——Interpreting Lu Xun s Prose Poem Tombstone Inscription;
否则 ,离开——鲁迅散文诗《墓碣文》破解
2)  isolator
隔离开关
1.
Overvoltage incident due to500kV isolator operation in Shanghe substation;
上河变电所500kV隔离开关操作中感应过电压事故分析
2.
Through a practical overhaul case of high voltage circuit breaker and isolator, the paper expounds the faults caused by difficulties of the circuit breaker in closing and makes corresponding measures.
通过高压断路器和隔离开关的实际检修工作 ,论述了导致断路器合闸困难的缺陷成因以及相应的处理方法。
3.
The effect of isolator operation on the selectivity of medium inpedence and digital bus-bar protections are analysed.
详细分析了操作隔离开关对中阻抗及微机母线保护选择性的影响 ,指出在进行隔离开关合、分闸操作过程中 ,若母线发生故障 ,存在导致扩大故障范围和造成人身伤亡的可能性 ,最后给出一些意见和设
3)  disconnector
隔离开关
1.
Improvement on suppression of birds harm for GW5 disconnectors;
GW5隔离开关防鸟害方案
2.
Analysis of Abnormal Phenomenon in Operation and Overhaul for GW4 Series Switch - disconnector;
对GW4系列隔离开关运行检修中异常现象的分析
3.
Analysis of the operation of disconnector in Shandong Power Grid;
山东电网高压隔离开关运行分析
4)  disconnecting switch
隔离开关
1.
In the process of switching operation of 220kV primary equipment,the switch of motor power source tripped suddenly,and then electric arc occurred between the moving contact and stationary contact of disconnecting switch.
对一起因220kV一次设备在倒闸操作过程中,电动机电源开关突然跳闸,致使隔离开关动、静触头之间产生电弧,危及电网和设备安全的这一危险情况进行了分析,找出危险根源,强调执行反事故措施的重要性。
2.
After comparing the operation condition of the improved high-voltage disconnecting switch of 110 kV and above with that of the initial one,the defects of the improved switch found in the operation of Sichuan power grid are pointed out,and the improvement suggestions are proposed.
通过对110 kV及以上高压隔离开关完善化前后运行状况的分析,指出了完善化后产品在四川电网运行中发现的缺陷并提出了改进建议。
3.
Concerning the faults frequently occurred during the operation of disconnecting switches,the factors affecting the safe and reliable operation of HV disconnecting switches were analyzed,and ways to strengthen the operation management of HV disconnecting switches and measures to improve equipment reliability were put forward.
针对隔离开关在运行中的常见故障,分析了影响高压隔离开关运行可靠性的原因,提出了加强高压隔离开关的运行管理及提高其运行可靠性的对策。
5)  isolation switch
隔离开关
1.
It is introduced the development background, procedures and handling of critic technologies of the 3 sub-systems in automatic track management system for locomotive depot, which are the centralized control of turnoffs, centralized control of isolation switches in electric locomotive depot along with operation monitor in service yard.
介绍了机务段股道管理自动化系统中道岔集中控制、电力机务段隔离开关集中控制、整备场作业图像监视3个子系统的研制背景、研制过程及关键技术的处理。
2.
A new product HSG1 series isolation switch was introduced.
介绍了一种新产品——HSG1系列隔离开关。
6)  isolating switch
隔离开关
1.
Research on improving of isolating switch;
离开关改造问题的研究
2.
Discussion on improving mechanical interlock of GW_(5A)-35,66,110 isolating switch;
关于GW_(5A)-35、66、110型隔离开关机械联锁改进的讨论
3.
Research on improving the performance of GW_5-110 isolating switch;
GW_5-110型隔离开关性能改进的研究