说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 联合运行策略
1)  cooperating tactic
联合运行策略
1.
This paper is based on the sanxia project, which is being built, and will illustrate the choice of firepower base for sanxia hydropower and the cooperating tactic of running hydropower and firepower to lower the energy consuming.
(3)在水电和火电的联合运行策略的前提下,论文以经济性为目标论述了火电机组负荷智能分配策略。
2)  operation policy
运行策略
1.
Hedging-rule modeling and mix-integer programming model, which are most common methods for obtaining reservoir operation policy, are expounded appropriately.
阐述了干旱期供水工程运行调度研究的必要性以及目前水资源研究领域普遍使用的表达干旱期供水水库运行性能的一些主要指标 ;对普遍使用的求解运行策略的限制供水规则模型和混合整数规划模型进行了恰当描述 ;最后介绍了混合整数规划模型的一应用实例 ,说明研究方法的可行
3)  operation strategy
运行策略
1.
Aiming at the operation strategy of CCHP plants, establishes a bi-objective programming model to minimize both the annual running cost and the annual primary energy consumption.
针对热电(冷)联产系统的运行调节问题建立了包含经济性和节能要求的双目标规划模型,根据热、电、冷负荷的全年变化提出了合理的运行模式和运行方案,探讨了经济性和节能要求的权重变化对总目标函数的影响,分析了分时电价、燃料价格对系统运行策略的影响。
2.
The optimization of facilities scheme and operation strategy on a cogeneration system was analyzed.
对一联供系统的设备配置与运行策略集成优化进行了分析。
3.
In this paper,combined with the requirements of subway operation,the operation strategy,operation mode and control of ice storage system are introduced.
结合地铁的运营需求,介绍了冰蓄冷系统在地铁中应用的运行策略、运行模式及其控制。
4)  operational strategy
运行策略
1.
Take a building as an example, study of configuration optimization and operational strategy is done.
介绍了微燃机冷热电联供系统的组成及其主要设备特性;分别从微燃机的温比、回热度和压比等方面对冷热电联供系统进行了热力学分析,并对其一次能源节约率进行了敏感性分析;利用数学规划的思想,以发电、制冷和供热设备的性能参数为优化的约束条件,建立了年运行费用最低的目标函数,并以某建筑为例,在给定的能源价格和冷热电负荷条件下,对微燃机冷热电联供系统进行了配置优化和运行策略分析;采用热经济学方法,考虑经济和技术等因素,提出了冷热电联供系统的优化改进意见;最后,采用灰色关联法和层次分析法,综合考虑经济、环保、节能和可靠性等指标,建立了冷热电联供系统分析评价的数学模型,对选定的多个楼宇冷热电联供系统方案进行了优化,确定了最优方案。
5)  combined operation
联合运行
1.
The measurement results indicate that the system operation efficiency during day and night can all be improved for the combined operation mode,and the superfluous solar energy during daytime may be stored temporarily by the U-tube for the use of night.
在已建成的太阳能-地热能综合利用多功能热泵试验系统上进行了太阳能-地源热泵系统联合与交替供暖运行特性的试验测试,结果表明:联合运行模式不仅可以提高日间系统运行效率,且U型埋管可作为热源缓冲体自动储存日间富余太阳能,以改善夜间运行效率,联合运行测试期内太阳能与地热能热源的承担比例为43。
2.
The characteristics of hydro power generation,wind power generation and their complementation are analyzed, a linear programming model for combined operation of hydro and wind power generation system was built.
对水电、风电的特点及其互补性进行了分析,建立了水电-风电优化联合运行的线性规划模型,用水电厂的历史入库流量和风电场的实测风速研究了水电厂和风电场各自单独运行、理想联合运行及优化联合运行,揭示了水电以其容量支持风电和风电以其电量支持水电的水电-风电互补特性。
6)  joint operation
联合运行
1.
The joint operation impact analysis of the Three Gorges cascade and the Qingjiang cascade power stations;
三峡梯级和清江梯级联合运行影响分析
2.
Research in joint operation program of air-condition and seawater desalination;
空调与海水淡化联合运行方案研究
3.
Considering the features of multiannual reservoir, this paper establishes a compensation adjustment and joint operation model, and presents an algorithm of man-machine interaction, which is based on equal power compensation adjustment calculating and attended by decision makers.
结合多年调节水库特点,本文建立了多年调节水库补偿调节联合运行模型,提出了一种基于等出力补偿调节计算、决策者参与的人机对话算法,通过实例计算表明,该算法具有计算速度快、占用内存少、决策者参与计算等优点,是解决多年调节水库联合运行计算的有效途径,具有重要推广、实用价值。
补充资料:燃气-蒸汽联合循环机组运行


燃气-蒸汽联合循环机组运行
operation of gas-steam combined cycle unit

  ronq卜zhengq{l一onhe xunhuon Jlzu yunx{ng姗气一燕汽联合循环机组运行(operation ofgas一steam eombined eyele unit)燃气一燕汽联合循环机组投人使用的整个过程,包括起动、正常运行和停机等有关内容。 有烟气旁通阀机组的起停首先把烟气旁通阀切换到通向大气的位t.无需考虑燕汽系统的影响使嫩气轮机单独起动、并网和带负荷.此时,嫩气轮机的排气全部绕过余热锅炉,直接排人大气。此后,可逐渐调节烟气旁通阀的挡板开度,控制进人余热锅炉的燃气流蛰,使燕汽系统缓慢地起动。倘若余热锅炉在冷态条件下起动,应限定进人余热锅炉的嫩气温度,否则过热器无法承受。只有当燕汽压力达到额定值的40%~60%,并有50~60℃的过热度后,才能起动汽轮机。在汽轮机能够接受全量的蒸汽之前,应将蒸汽通过汽轮机的旁路阀送人凝汽器。若烟气旁通阀不严密,为了预防在起动燃气轮机时有可能残存在余热锅炉中的少量燃料被引姗而爆炸,应使燃气轮机在点火转速下,不喷燃料且不点火地运转几分钟,用空气来吹扫余热锅炉的流道。随后把烟气旁通阀切换到通向大气的位里.在机组故障或大修后的首次起动时,这种吹扫工作也必须进行。停机时应先使燃气轮机卸负荷,汽轮机也相应地减负荷。当燃气轮机的排气温度降到所规定的某值时,就该停运汽轮机。因那时产生的燕汽已无法使汽轮机输出净功.此后应进一步减少燃气轮机的负荷,直至使其停运,随即应把烟气旁通阀切换到直通大气的位置。若余热锅炉有补嫩装置,只有当燃气轮机带上满负荷,汽轮机已接受了全流量蒸汽之后,补燃装工才能投运.停机时,首先应停运补燃装置,随后才降低燃气轮机的负荷,并按上述顺序执行停机过程。 没有烟气旁通阀机组的起停为了防止爆炸,在嫩气轮机点火前,应首先用起动机带动燃气轮机,使它在点火转速下,不喷燃料且不点火地运行几分钟,以吹扫余热锅炉。此后,燃气轮机点火起动,但带负荷的速度不宜太快,以防余热锅炉汽包升温速率超过最大允许值。对于单轴联合循环机组来说,在厂内有其他燕汽的前提下,可以用汽轮机作为起动机来起动嫩气轮机,随着燃气轮机带上负荷后,余热锅炉逐渐进人工作状态,并向汽轮机供应蒸汽,以取代外界燕汽源对汽轮机的供汽。 停机过程与有烟气旁通阀的机组没差别. 热态起动与冷态起动机组有热态起动和冷态起动之分。当机组停机8~14h后立即起动者称热态起动,它能够在20~50min内带上全负荷。在这种情况下,联合循环机组能够满足电网要求紧急起动进行调峰的需要。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条