说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 隔离铁心变压器
1)  isolated core transformer
隔离铁心变压器
2)  isolation transformer
隔离变压器
1.
Application of isolation transformer in synchronous voltage loop of non-synchronous close in double-side circuit breaker of transformer;
隔离变压器在变压器双侧断路器非同期闭锁合闸同期电压回路中的应用
2.
Type HXD1 locomotive uses integrated auxiliary power supply system,which auxiliary inverter is integrated in the traction inverter,the power of auxiliary inverter is obtained directly from the traction DC link and is made available with a isolation transformer and a filter.
在HXD1型机车上,采用集成式辅助电源模式,即将辅助逆变器集成于牵引变流器中,电源直接从牵引直流电路获得,再通过隔离变压器加滤波的形式为辅助电路供电。
3.
If there are two ways of different voltage transformer secondary earthing (B earthing point,N earthing point)in a power plant or a substation, we must make a right conclusion through phasor analysis in secondary checking phase ,we may use corresponding voltage through isolation transformer to solve the problem of different earthing point in corresponding.
当一个电厂或电站的不同电压等级PT二次接地点存在两种接地方式(B相接地,N相接地),我们在二次核相时,应通过相量分析,才能得出正确结论,在同期方面,应通过隔离变压器引入同期电压,以消除不同接地点的影响。
3)  transformer isolation
变压器隔离
1.
A new type of primary-side-assisted ZVZCS DC-DC converter with transformer isolation is presented.
提出了一种采用原边辅助型变压器隔离的零电压和零电流开关(ZVZCS)直流-直流变频器。
4)  transformer core
变压器铁心
1.
Research on transformer core on-line monitoring based on fiber F-P sensors
基于光纤F-P传感器变压器铁心在线监测研究
2.
In the working process of transformer,multi-point grounding of the transformer core could lead to too big grouding current which can burning the core.
在电力变压器运行过程中,为了预防因铁心多点接地导致接地电流超标而造成的铁心过热和烧毁故障,设计了一种基于无线数据传输技术的变压器铁心接地电流在线监测系统;该系统能够实现对变压器铁心接地电流的实时或定时监测和历史数据的存储,能够在检测到接地线电流超过国家标准后发出报警信号,同时根据电流的大小实现限流电阻的自动投切,最终将接地电流限制在规程要求的范围之内;应用nRF905无线射频收发芯片设计了无线通讯模块,实现了下位机与上位机的无线数据传输。
3.
For round-the-clock and real-time monitoring of the transformer core grounding fault and timely treatment,the current and voltage in the grounding loop of a transformer core under the condition of single point or multi-point grounding were analyzed.
为了全天候实时监测变压器铁心接地情况并能及时进行故障处理,笔者分析了单点和多点接地时铁心接地回路中的电流和电压,采用监测接地线电流的方法设计了一种监测及限流装置,实现了接地线电流的实时监测和限流电阻的自动投切,将电流限制在规程要求的范围之内,避免了铁心过热和烧毁事故。
5)  parametric drawing design
变压器铁心
1.
Based on Databse of Transformer Iron Parametric Drawing Design;
基于数据库的变压器铁心参数化绘图设计
2.
This paper introduces the design example which make use of AutoLISP and DCL to realize the parametric drawing design of transformer iron,discuss such as establish the design paramertric,design interface,auto calculate scale of the drawing,draw the view and the use method of data file.
介绍了利用AutoLISP与DCL语言实现变压器铁心参数化绘图的设计实例,讨论了其设计参数的确定、界面设计、绘图比例自动计算、视图绘制及数据文件的使用方法,极大地提高了产品的开发效率,有一定的推广价值。
6)  core type transformer
铁心变压器
补充资料:隔离变压器
      用以对两个或多个有耦合关系的电路进行电隔离的变压器。其变比为1。在电力系统中,为了防止架空输电线路上的雷电波进入室内,需经过隔离变压器联络。即使架空线路电压与室内电路电压相等,例如发电厂对附近地区的供电电压与厂用电电压就可能相等,此时也需用隔离变压器联络而不直接联接。隔离变压器除变比为1外,与普通变压器无其他区别。利用隔离变压器的漏电感和端子的对地放电间隙及对地电容,就可以使雷电波,特别是其高频部分,导入大地而不进入变压器,从而使室内电路免受雷电的损害。隔离变压器在电子电路以及精密测量技术中有着更广的应用。
  
  一般变压器原、副绕组之间虽也有隔离电路的作用,但在频率较高的情况下,两绕组之间的电容仍会使两侧电路之间出现静电干扰。为避免这种干扰,隔离变压器的原、副绕组一般分置于不同的心柱上,以减小两者之间的电容;也有采用原、副绕组同心放置的,但在绕组之间加置静电屏蔽,以获得高的抗干扰特性。
  
  静电屏蔽就是在原、副绕组之间设置一片不闭合的铜片或非磁性导电纸,称为屏蔽层。铜片或非磁性导电纸用导线连接于外壳。有时为了取得更好的屏蔽效果,在整个变压器,还罩一个屏蔽外壳。对绕组的引出线端子也加屏蔽,以防止其他外来的电磁干扰。这样可使原、副绕组之间主要只剩磁的耦合,而其间的等值分布电容可小于0.01pF,从而大大减小原、副绕组间的电容电流,有效地抑制来自电源以及其他电路的各种干扰。
  

说明:补充资料仅用于学习参考,请勿用于其它任何用途。