说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 光缆接头
1)  optical cable splice
光缆接头
2)  Cable joints
光缆接头器
3)  closure [英]['kləʊʒə(r)]  [美]['kloʒɚ]
光缆接头盒
1.
Aiming at the problem of water-intrusion into closures in fiber optic cable operation and maintenance,and based on the description of the causes and harm of water-intrusion,a water-intrusion detecting sensor for fiber optic cable closure,which makes use of water-blocking tape,is designed and fabricated.
针对当前光缆运营、维护中出现的接头盒浸水不能实时监测的难点问题,在简述接头盒浸水成因,论述其危害的基础上,结合实际运用,提出了利用膨胀阻水带,设计制作光缆接头盒浸水监测传感器,以有效地对光缆接头浸水受潮进行实时监测。
2.
The closures for fiber optic cables are the indispensable devices in optical fiber communication links,and they play very important role in protection of the connection between optical fibers and cables,and the communications quality in optical fiber links.
光缆接头盒是光纤通信线路中不可缺少的部件,它对光纤光缆的连接保护、光缆线路通信质量起重要的作用。
3.
The water ingression into closures is a common fault in the case of buried fiber optic cable links.
根据实际光缆线路整修中发现的问题,简要地探讨了诱发直埋光缆接头盒进水的成因和危害;并依据整修中所获得经验,提出了相应的处理措施。
4)  cable joint
电缆接头
1.
Localized assumption on cable joint of type DJ4 locomotive;
DJ4型机车电缆接头国产化设想
2.
It has become an important factor of evaluating the performance of power cable joint.
为准确测量高压电缆接头的界面压力以保障接头电气性能良好,设计了橡胶件界面压力测试装置,它采用一个与电缆外径相同的铝质薄壁管,在内部粘贴应变片,用电测法测量橡胶件施加载荷时内壳壁的应变量,再利用有限元分析获得外壁界面压力值。
3.
The measurable temperature parameters of various stations are calculated and forecasted by a higher management computer, realizing alarm-giving for power cable joint fault in advance.
介绍了参数估计模型的最小二乘法和温度预报的方法,由上位管理机对多站各点的可测温度变量参数进行计算和预报,实现对电力电缆接头故障发生的提前报警。
5)  cable connector
电缆接头
1.
The processing technology and the design of the tooling for the cable connectors used in the high_ and low_voltage switch equipment were introduced.
介绍了高低压开关设备中电缆接头的加工工艺及模具设计 ,较为详尽地介绍了电缆接头冷挤压成形模的结构特
2.
A kind of connector matching with Q9 series cable connector,which leads high fre-quency signal from vaccum cell introduced in this paper.
介绍了一种与Q9系列电缆接头相配,将高频信号从真空室引出的密封接头。
6)  cable tie-in
电缆接头
1.
Development of cable tie-in temperature checking,early-warningand blast-proof system;
电缆接头温度检测、预警及防爆系统的研制
2.
Due to over-heated on the cable tie-in, the breakdown may cause a large area power off.
由于电缆接头的过热崩烧故障,可能引起大面积停电。
补充资料:换流变压器分接头控制


换流变压器分接头控制
tap changer control of converter transformer

huon}lub{anyoq一fenJ一etou kongzhl换流变压价分接头控制(tap ehanger eontrolofeonvertertransformer)直流物电控制系统中用于自动调整换流变压器有载调压分接头位里的一个环节,属极控制层次(见直流堵电控制系统分层结构).分接头控制的目的是为了维持整流器的触发角(或逆变器的关断角)在指定的范围内或者维持直流电压或换流变压器阀侧绕组空载电压在指定的范围内.其控制策略需要与换流器控制方式相配合,通常可分为角度控制和电压控制两大类。 角度控制当整流器使用直流电流控制时,通过调整换流变压器分接头位t,把整流器触发角维持在指定范围内(如15.士2.5,);当逆变器使用直流电压控制时,通过调整换流变压器分接头位!,把逆变器关断角维持在指定范围内(如18.士2.5。)。当触发角瞬时超过限定范围时,不应使抽头调节器动作,以免抽头调节机构来回频公动作.因此,应规定一个时滞,只有当触发角连续超过限定范围的时间大于此时滞时,才允许起动抽头调节机构。 电压控制当逆变器使用关断角控侧时,通过调整换流变压器分接头位t,把直流线路电压维持在指定范围内,如。.98~1.02额定直流电压.同样,为了避免抽头调节机构来回频萦动作,只有当直流电压偏离其整定值达到一定值,且持续一定时间后(例如直流电压偏离额定值士1%且超过55),才起动抽头调节。另一种电压控制策略是通过调整换流变压器分接头位里,把整流器(或逆变器)的换流变压器阀侧绕组空载电压维持在指定值。 角度控制方式与电压控制方式相比,其优点是:换流器在各种运行工况下都能保持较高的功率因数,即愉送同样的直流功率,换流器吸收的无功功率较少.其缺点是:分接头动作次数较频繁,因而检修周期会短些。此外,分接头调压范一围也要求宽些. 由于换流变压器分接开关至今都是机械式的,转换一档通常需要3~5s的时间,对控制的响应很慢。它是调整直流翰电系统翰送功率的辅助手段。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条