说明:双击或选中下面任意单词,将显示该词的音标、读音、翻译等;选中中文或多个词,将显示翻译。
您的位置:首页 -> 词典 -> 双母线双分段
1)  double-bus double-segment
双母线双分段
1.
Through analysis and improvement of construction project of double-bus double-segment and bus differential protection of 200 kV system in 500 kV Xin\'an substation,the improvement is put forwards,which is to reduce times of line power cutting during reconstruction,and to keep the integrity of original bus protection and to maintain its running in construction.
通过对辛安500 kV变电站220 kV系统双母线双分段接线方式的施工方案进行分析和改进,提出一种在改造施工中减少线路断电次数,保持原母差保护完整运行的施工方案。
2)  dual-bus dual-subsection
双母双分段
1.
Problems encountered during the retrofit and debugging of bus protections for dual-bus dual-subsection wiring were analyzed and solutions were proposed.
阐述了改造原则是保证母线保护的完整运行,介绍了施工方案以及双母双分段母线保护在施工和调试中的问题及解决。
3)  duplicate-bus duplicate-segmentation connection
双母线双分段接线
1.
It presents the bus protection of the duplicate-bus duplicate-segmentation connection based on decomposition and combination method and describes the implementation of differential relaying protections.
介绍了某220kV开关站一次接线由原来的双母线带旁路接线改造为双母线双分段接线的配置方案,提出了采用分解组合法来配置和实现基于一次接线为双母线双分段接线的母线保护,阐述了双母线双分段接线的母差保护的实施办法,2年多的运行证明了保护装置的有效性。
4)  4-section busbar system
双母联双分段
1.
The protection configuration of 4-section busbar system was introduced and the protection connection principle was analyzed.
介绍了双母联双分段母线保护配置方式,分析了双母联双分段母线系统保护接线原理,尤其是死区保护及分段断路器失灵保护的动作原理和逻辑,以及分段电流互感器接入母线保护的极性问题。
5)  piecewise bilnear function
分段双线性函数
6)  double-bus
双母线
1.
In order to improve the power supply s reliability,Programmable Logic Controller(PLC) is used to replace relays,for realizing the main adjoin wire——double-bus when it changes bus,the operation course of the disconnectors and circuitbreakers.
为提高供电的可靠性,用可编程序控制器(简称PLC)代替继电器实现电气主接线——双母线切换母线时隔离开关和断路器的操作过程。
2.
Thus it is important to make analysis and judgment on transfer switching correctly to avoid fault evolving when the differential protection on one of the double-bus.
对GIS双母线接线运行变电站在某一条母线差动保护动作情况下,怎样进行正确判断分析、倒闸操作,才能避免事故的扩大提出建议,以供调度和变电运行人员参考。
补充资料:均衡母线接线


均衡母线接线
balance-bus scheme

均衡母线接线个发电机一变压器-。黑蓄竺亡尝、整eme,每-,一“~华/‘侧p理迈另一合断改段位到一组公共均衡母线的主接线方式.这种接线是由变压器一线路组接线演变而成,增设了均衡母线,可使各回路间电能均衡分配。也可认为是一个半断路器接线去掉一组母线和一台断路器的简化接线方式。按均衡母线断路器位置,可分为外均衡母线接线(均衡母线断路器接在线路侧)和内均衡母线接线(均衡母线断路器接在变压器侧),分别见图(a)、(b)。┌───┬─────┬────┐ ├挚¨┐│ 1 │.、 │ │ 、│├蛰-%┐ │ │ │ ││ 、│ ├───┬┼─┐├──┴┼──┘ │.臼.- ││ ││} │ │ 班 ││ ││ │ ├───┘└─┘└───┴─────┘ 均衡母线接线 (a)外均衡母线接线,(b)内均衡母线接线 这两种接线方式的共同优点是:①接线清晰.②布置简单。③运行方便,故障影响范围小,运行可靠性较高,尤其对线路物送功率和发电机容量相当,或者输电线路基本送往同一方向或同一变电所时最为适用。共同缺点是:①灵活性差,均衡母线检修,全部解列成各自单独的发电机一变压器一线路组单元运行.②均衡母线上的断路器故障,除影响本回路变压器一线路组单元停电外,其他单元也将解列运行。 外均衡母线接线的优点是:①主变压器的投人或切除比较方便。②一台主变压器故障只开断一台断路器,不影响线路的运行。缺点是:①出线断路器检修将影响发电机变压器组送电。②线路故障需同时开断两台断路器,并需满足并联开断的要求。 内均衡母线接线的优点是:①线路的投人或切除比较方便。②一回线路发生故障时,仅故障线路的断路器断开,不影响其他回路的运行.缺点是:①一台主变压器故障,同时开断两台断路器,并切除一回线路。②主变压器的投入或切除需同时开断两台断路器,并影响线路的运行。 均衡母线接线一般适用于进出线回路数相同,出线负荷较稳定,且负荷基本与发电机容量相一致,并且电力系统允许按发电机一变压器一线路组单元运行的大中型水电站.当电站利用小时数较低,担负调峰任务,主变压器切合频萦时,一般采用外均衡母线接线。
说明:补充资料仅用于学习参考,请勿用于其它任何用途。
参考词条