Some shortcomings of the traditional coatings for iron core of electric steel are expounded.
阐述了电工钢传统涂层在固定铁芯方面存在的不足之处。
2.
5MVA furnace transformer iron core connecting with the ground is introduced.
5MVA电炉变压器铁芯接地故障的检查,并通过在现场采取有效的处理办法,解决了变压器运行中存在的局部过热现象,保障了变压器的安全稳定运行。
3.
Directing against the disadvantages shown and brought about by the stabilizer′s iron core air gap of common discharging lamps, a new type of stabilizers is developed for the airless gap discharging lamps.
针对一般放电灯镇流器铁芯气隙所伴随的缺点,研制了一种新型无气隙放电灯镇流器,它用加入了铁磁性材料的胶粘剂将四段硅钢片用粘接到一起。
3)  core
铁芯
1.
Diagnostic and Processing Method of Transformer Core with Grounding Fault in Multiple Spots;
变压器铁芯多点接地故障的诊断及其处理方法
2.
Study on Searching Method of Transformer Core Earth Fault;
变压器铁芯接地故障的查找方法
3.
Diagnosis and Treatment of Iron Core Multipoint Earth Fault of Lijiaxia Substation s 2~# Main Transformer;
李家峡变电所2~#主变铁芯多点接地故障诊断与处理
4)  cores
铁芯
1.
he factors which affecting the detecting signals of the rund amorphous,cores and the parameters of its size are analyzed.
从理论上分析了影响非晶态环形铁芯检测信号的因素和环形铁芯设计的参数依据,针对相应的因素,提出了改善非晶态环形铁芯的热处理和绕制工艺以提高它检测信号数值及其均匀性的解决办法,并用试验证实了这一设想的可行性。
2.
High power inverter cores made of nanocrystalline FeNbCuSiB alloy are introduced.
介绍了一种FeNbCuSiB纳米微晶合金铁芯 ,这种铁芯具有低损耗、低剩磁和高磁导率等优良磁性能。
5)  iron-core
铁芯
1.
Analysis on iron-core multipoint earthing fault of transformer and its treatment method;
变压器铁芯多点接地故障分析及处理方法
2.
The following paper introduces several types of common happened iron-core multipoint earthing fault of transformer and their causes,proposes their processing methods and procedures and points out that accurately and timely diagnosing and treating the earthing faults has important meaning to ensure safety operation of transformer.
介绍了变压器常发性故障——铁芯多点接地的几种类型及其成因,提出了变压器铁芯多点接地故障的简易处理方法及处理步骤,指出准确及时地诊断与处理变压器铁芯多点接地故障,对保证变压器的安全运行具有重要意义。
3.
This paper gives a particular description for the reasons about what is wrong with transformer s iron-core connecting to earth in some points.
详细介绍了变压器常发性故障—铁芯多点接地的几种类型及成因,从而提出变压器铁芯多点接地故障的分析处理程序并列举了两个处理实例进行说明。
6)  iron chip
铁芯片
参考词条
补充资料:Z8612热芯盒射芯机操作规程
1、遵守铸造设备通用操作规程。
2、工作前还必须遵守:
a、
检查设备上行程开关和碰块的位置是否正确,如不正确,必须调整。
b、
接通电源,打开压缩空气伐门,先用手动方法,对各机构逐进行点动试车,然后用自动方法,进行一个循环试车,确认一切正常后,方可进行生产。
3、工作中还必须遵守:
a、
在设备开动后,一个循环未完成时,不许中途调整电器,以免发生误动作,造成设备人身事故;
b、
设备的每一个循环后,必须用喷咀清除芯盒上残存的砂子,并喷涂分型剂;
c、
在未切断电源和所气源前,不准将手伸入芯盒和夹紧器之间的空隙处,或把手放在导轨上,以免发生人身事故。
d、 一般不准空射,如必须空射,一定要把压缩空气伐门关小;
e、 如果用手操作,不准同时操作两个电器开关。
4、工作后还必须遵守:
a、
操纵各个电器开关,使设备各机构恢复到原始位置,然后切断电源和气源;
b、 折下射砂头,清理积砂和粘砂;
c、 清除排气塞内的粘砂;
d、
取下射砂筒,清除缝隙中的粘砂,最后用石蜡涂擦内壁,但不要将缝隙堵塞;
e、 清除闸板上的积砂,并在闸板上涂石墨粉,以减少磨擦;
f、 清除导轨和导杆上的积灰和积砂,并涂上一层润滑油。